500590
20
Zoom out
Zoom in
Previous page
1/40
Next page
20
Zentral
Thermostat
7. Verdrahtung Installation 3: Wärmepumpe (Umschaltung über Sensor)
DIP switch
Konfiguration
S1 & S2
B1
Kühlaus-gang
B2
Heizaus-gang
B3
Trockner
P1
Grenztemperatur
P2
Hysterese
ON
OFF
1
2
Nicht
angeschlossen
Nicht
angeschlossen
Wird über Zentral
Programmer
Thermostat
gesteuert
5 to 25 °C
Bei
Unterschreitung
wird das System
in den Kühlmodus
geschaltet
1 to 10°C
Hysterese bei
welcher Temperatur
wieder in
Heizmodus
umgeschaltet wird
Stellantriebe für
Zentral Thermostat
A B 1 HC Sen 2 4
NC
24Vac
B1 B2 B3
NC
24Vac
P1
P2
S1
L N
Trockner
Externer Temperatur Fühler zur
Taupunktüberwachung (optional)
Sensor muss temperaturschlüssig am Vorlauf
des Heizungssystems angebracht sein!!
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Radson 51035 - H-C module 24V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Radson 51035 - H-C module 24V in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 0,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info