Parameters
Names
Description
Default setting
Other possibility
00
XXx
Sofware version
01
Deg
Type of degrees displayed
°C: Celsius degrees.
°F: Fahrenheit degrees.
02
Out
Actuator type
NC: Normally closed actuator.
NO: Normally open actuator.
03
Sen
Selection of the sensor which will
be used for the regulation.
The listing of the following
parameters will be different in
function of this parameter.
Air: ambient sensor only
Flr: External (floor) sensor only.
FL.1: ambient sensor with lower and upper floor limitation.
FL.2: ambient sensor with intelligent lower floor limitation.
04
AiC
Calibration of the internal sensor
(The calibration must be done after
12Hours working with the same
setting temperature)
- To check the temperature in the room, put a thermometer at 1.5M
distance to the floor in the concerned room and wait 1 hour to be
sure that the thermometer show the correct temperature. Then you
can enter the value saw on the thermometer with (-) or (+) keys.
- When a calibration is made the message “Yes” will be displayed.
- To erase the calibration press simultaneity (-) and (+) keys when
Yes” is displayed. Now the message “no” should be displayed.
05
FlC
Calibration of the Floor sensor
(The calibration must be done after
12Hours working with the same
setting temperature)
The calibration must be done same as described above if the
external sensor is connected and used like an external ambiance
sensor.
If the external sensor is used as floor sensor, the thermometer
should be put on the floor.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Radson 51022 - DIGITAL 24V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Radson 51022 - DIGITAL 24V in the language / languages: English, German, Dutch, French, Polish as an attachment in your email.

The manual is 0,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Radson 51022 - DIGITAL 24V

Radson 51022 - DIGITAL 24V Installation Guide - English, German, Dutch, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info