Batteries and Charging
Your power chair uses two long-lasting, 12-volt, deep-cycle
batteries. These batteries are sealed and maintenance
free. Since they are sealed, there is no need to check the
electrolyte (fluid) level. Deep-cycle batteries are designed
to handle a longer and deeper discharge. Though they are
similar in appearance to automotive batteries, they are not
interchangeable. Automotive batteries are not designed to
handle a long, deep discharge, and also are unsafe for use
in power chairs.
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
Contact your Quantum Rehab Provider if you have any
questions regarding the batteries in your power chair.
Always use two batteries of the exact same type,
chemistry, and amp-hour (Ah) capacity. Refer to
specifications table in this manual and in the manual
supplied with the battery charger for recommended type
and capacities.
Charging the Batteries
The battery charger is essential in providing long life for your
power chair batteries. It is designed to optimize your power
chair’s performance by charging the batteries safely, quickly,
and easily.
PROHIBITED!
MANDATORY!
WARNING!
BATTERIES AND CHARGING
PROHIBITED! Removal of grounding prong can
create electrical hazard. If necessary, properly
install an approved 3-ponged adapter to an
electrical outlet having 2-pronged plug access.
PROHIBITED! Never use an extension cord to
plug in your battery charger. Plug the charger
directly into a properly wired standard electrical
outlet.
PROHIBITED! Do not allow unsupervised
children to play near the power chair while
the batteries are charging. Quantum Rehab
recommends that you do not charge the
batteries while the power chair is occupied.
MANDATORY! Read the battery charging
instructions from this manual and in the manual
supplied with the battery charger before
charging the batteries.
WARNING! Explosive gases may be generated
while charging the batteries. Keep the power
chair and battery charger away from sources
of ignition such as flames or sparks and
provide adequate ventilation when charging the
batteries.
WARNING! You must recharge the power chair
batteries with the supplied off-board battery
charger. Do not use an automotive-type battery
charger.
WARNING! Inspect the battery charger, wiring,
and connectors for damage before use. Contact
your Quantum Rehab Provider if damage is
found.
WARNING! Do not attempt to open the battery
charger case. If the battery charger does not
appear to be working correctly, contact your
Quantum Rehab Provider.
WARNING! Be aware that the battery charger
case may become hot during charging. Avoid
skin contract and do not place on surfaces that
may be affected by heat.
WARNING! If the battery charger is equipped
with cooling slots, then do not attempt to insert
objects through these slots.
WARNING! If the battery charger has not been
tested and approved for outdoor use, then do
not expose it to adverse or extreme weather
conditions. If the battery charger is exposed to
adverse or extreme weather conditions, then it
must be allowed to adjust to the difference in
environmental conditions before use indoors.
Refer to the manual supplied with the battery
charger for more information.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quantum Q6 Edge 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quantum Q6 Edge 2.0 in the language / languages: English as an attachment in your email.

The manual is 14,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quantum Q6 Edge 2.0

Quantum Q6 Edge 2.0 User Manual - German - 32 pages

Quantum Q6 Edge 2.0 User Manual - Dutch - 28 pages

Quantum Q6 Edge 2.0 User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info