CARE AND MAINTENANCE
13. Connect the battery harness to the new front battery
according to the battery wiring diagram. See figure 21.
14. Connect the battery harness to the new rear battery
according to the battery wiring diagram. See figure 21.
Make sure you tighten the fasteners so that the
connections are secure.
15. Install the new rear battery by lowering it into the power
base. Ensure the actuator is straight up and down next
to the rear battery. Connect the quick release battery
connectors to the new rear battery.
16. Install the new front battery by sliding it into the front
of the power base. Connect the quick release battery
connectors to the new front battery.
17. Reinstall the top cover by sliding the rear of the top cover
under the lip of the rear door and then sliding into place.
18. Reinstall the front cover.
19. Return the seat to an upright position.
20. Reinstall the detent pin into the top of the actuator and
ensure that it is secure. See figure 4.
21. Reinstall six (6) Phillips flat head screws if seat pan was
removed.
22. Tighten the rear pivot hardware.
23. Charge the batteries. See “Batteries and Charging.
Battery Replacement
A battery wiring diagram is printed on a decal located on
the front cover. See the specification table for correct battery
specifications.
Battery posts, terminals, and related accessories
contain lead and lead compounds. Wear goggles and
gloves when handling batteries and wash hands after
handling.
The batteries in your power chair should only be
serviced or replaced by a Quantum Rehab Provider or a
qualified technician.
Do not replace batteries when seat is occupied.
Power chair batteries are heavy. See specifications
table. If you are unable to lift that much weight, be sure
to get help. Use proper lifting techniques and avoid
lifting beyond your capacity.
Do not mix old and new batteries. Always replace both
batteries at the same time.
Keep tools and other metal objects away from the battery
terminals. Contact with tools can cause electrical shock.
To replace the batteries:
1. Turn off the power to the controller.
2. Make sure that the power chair is in drive mode. See
“Your Power Chair.
3. Loosen the rear pivot hardware until the Nylock nut is a
few threads from being removed.
4. Remove the detent pin from the top of the actuator. See
figure 4. If there is any difficulty in reaching the pin from
under the seat, the seat pan may be removed. Remove
six (6) Phillips flat head screws to remove the seat pan.
5. Pivot the seat toward the rear of the power chair and
support the seat in this position. Take care to ensure that
the recline actuator does not damage the rear door of
the power chair while the seat is pivoted rearward.
6. Remove the front cover by squeezing the release
handles (see figure 21) and lifting the front cover up
and away from the power base.
7. Remove the top cover by lifting it straight up and off of
the power chair.
8. Disconnect the actuator harness.
9. Disconnect the quick release battery connectors. See
figure 1.
10. Remove the front battery from the power base by sliding
it forward and out of the power base.
11. Remove the rear battery by lifting it up and out of the
power base.
12. Disconnect the battery harness from each battery.
PROHIBITED!
WARNING!
WARNING!
MANDATORY!
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quantum Q4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quantum Q4 in the language / languages: English as an attachment in your email.

The manual is 6,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quantum Q4

Quantum Q4 User Manual - German - 32 pages

Quantum Q4 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info