815529
7
Zoom out
Zoom in
Previous page
1/30
Next page
707/238105-804I
Model Outtter-II
Laboratory OMNITestLaboratories,Inc.
Report No. 0135PS041E,061-S-88-8.3
Type Solid Fuel Room Appliance/Pellet Fuel
Burning Type
Standard ASTME1509andULCS627Room
Appliance Pellet Fuel Burning type and
(UM)84-HUD,MobileHomeApproved.
A. Appliance Certication
NOTICE: This installation must conform with local codes.
Intheabsenceoflocalcodesyoumustcomplywiththe
ASTM E1509, ULC S627 and (UM) 84-HUD.
C. BTU & E󰀩ciency Specications
This pellet appliance needs periodic inspection and repair
for proper operation. Consult the owner’s manual for further
information.Itisagainstfederalregulationstooperatethis
pellet appliance in a manner inconsistent with operating
instructions in this manual.
EPA Certication
Number: 128-18
EPA Certied
Emissions: 0.53gramsperhour
*LHV Tested E󰀩ciency: 87.5%
**HHV Tested E󰀩ciency: 81.9%
***EPA BTU Output: 9,605to40,667perhr
****BTU Input: 11,676 to 49,207 per hr
Vent Size: 3” or 4” Type “L” or “PL”
Hopper Capacity: 130 lbs.
Fuel Premium Wood Pellets
*WeightedaverageLHV(LowHeatingValue)e󰀩ciency
using data collected during EPA emissions tests in
accordancewiththerequirementsofCSAB415.1.
**WeightedaverageHHV(HighHeatingValue)e󰀩ciency
using data collected during EPA emissions tests in
accordancewiththerequirementsofCSAB415.1.
***ArangeofBTUoutputscalculatedusingHHVe󰀩ciency
and the burn rates from the EPA tests.
**** Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
The OUTFITTER-II is Certied to comply
with 2020 particulate emission standards.
Model Outtter-II
Laboratory OMNITestLaboratories,Inc.
Report No. 0135PS041E
Standard ASTME2779andASTME2515
Can be found at:
www.quadrare.com/about-us/epa-certication
B. Appliance Emissions Certication
1 1 Important Safety Information
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Outfitter II - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Outfitter II - Pellet in the language / languages: English as an attachment in your email.

The manual is 4.45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Outfitter II - Pellet

Quadra-Fire Outfitter II - Pellet User Manual - French - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info