815520
2
Zoom out
Zoom in
Previous page
1/28
Next page
27094-803D 12/23
A. Sample of Serial Number / Safety Label
LOCATION:UNDERASHLIP,PULLOUTTOVIEW
NOTE: Clearances may only be reduced by means approved by the regulatory authority having
jurisdiction
and Welcome to the Quadra-Fire Family!
PREVENT HOUSE FIRES
Install and use only in accordance with manufacturer's installation, venting and operating
instructions.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA
Refer to manufacturer's instructions and local codes for precautions required for passing
chimney through a combustible wall or ceiling.
WARNING - For Mobile Homes: Do not
install in a sleeping room. An outside combustion air inlet must be provided and
unrestricted while unit is in use. The structural integrity of the mobile home floor, ceiling
and walls must be maintained. The insert must be properly grounded to the frame of the
mobile home. A complete relining of the chimney system with a 6 inch (152mm) diameter
listed stainless liner is required. Must be equipped with a spark arrestor cap. Outside Air
comes standard on the insert and must be installed before operating insert.
When used as a masonry insert stove, install only in a masonry fireplace built to national
and/or local codes. Do not remove brick or mortar to accommodate insert. Installation
requires a 5 foot minimum length of a starter pipe into existing chimney with airtight face
seal. A full reline with listed liner strongly reccomended.
Install only on a non-combustible hearth.
Approved for installation and use in factory built zero-clearance fireplaces conforming to
minimum fire chamber specifications. A complete relining of the chimney system with a 6
inch (152mm) diameter listed stainless liner is required.
In Canada a full length 6 inch (152mm) S635 flue liner is required as per ULC S628-93.
WARNING - Inspect and clean chimney frequently. Under certain conditions of use, creosote
buildup may occur rapidly.
Do not connect this unit to a chimney serving another appliance.
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Route
power cord away from unit. Do not route cord under or in front of appliance. Electrical
Rating: 115 VAC 1.4 AMPS 60 Hz
Do not use grate or elevate fire. Build wood fire directly on hearth (firebrick).
Do not
overfire. If heater or chimney connector glows, you are overfiring.
Operate only with doors
closed. Open only to add fuel to the fire. Replace glass only with 5mm ceramic available
from your dealer.
DO NOT REMOVE THIS LABEL
HOT WHILE IN
OPERATION DO NOT
TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE
NAMEPLATE AND INSTRUCTIONS.
CAUTION:
Factory-Built Floor
Protection under Hearth
Extension
Thermal & Ember Protection
Floor height 0 to 4.5 inches below
Insert Base: Materials with R value of
2.9 required.
Ember Protection Only
Greater than 4.5 inches below Insert
Base.
LISTED ROOM HEATER, SOLID FUEL TYPE
"For Use with Solid Wood Fuel Only."
Also for use in Mobile Home.
Made in U.S.A. of US and
imported parts.
7094-800A
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 crib wood particulate emission standards at 1.9 g/hr for single burn rate heaters.
This single burn rate wood heater is not approved for use with a flue damper.
This wood heater needs periodic inspection and repair for proper operation. Consult the owner’s manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner’s manual.
Mfg by:
352 Mountain House Road
Halifax, PA 17032
www.quadrafire.com
R
Serial No. / N° de série
HF
BARCODE LABEL
EXPEDITION I
CONFORMS TO UL STD 1482 AND CERTIFIED TO ULC STD S628
21-670
21-661
Side Wall
FF
Fuel Door
Insert
BB
Fascia
or Trim
Maximum Mantel Depth - 12 inch (305mm)
Mantel
Hearth Extension
AA
C
C
D
D
E
E
Minimum Clearances To Combustible Material
Masonry, Heat Circulating & Factory-Built
Refer to Clearances on other label for Canada
A Sidewall to Center of Appliance 24.5 in.
B Mantel to Bottom of unit 44.75 in.
C Top Trim to Bottom of unit 42.5 in.
D Side Trim to Center of Appliance 23.75 in.
E Hearth Extension from Glass 16 in.
F H
earth Extenson from Fuel Loading Door
8 in.
USA ONLY
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
2022 2023 2024
SAMPLE
Test Lab &
Report Number
Mfg Date
Serial Number
Model Name
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Expedition I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Expedition I in the language / languages: English as an attachment in your email.

The manual is 5.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Expedition I

Quadra-Fire Expedition I User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info