815522
25
Zoom out
Zoom in
Previous page
1/40
Next page
25 12/237021-802L
A. Blowers
1. Convection Blower
PART NUMBER: 812-4900
NOTE: The convection blower must be removed before
the exhaust blower can be removed.
Side Screws,
Loosen Do Not
Remove
Side Screws,
Loosen Do Not
Remove
Remove back screws and
bend top back leaving it
attached at the bottom
Figure 25.1
Remove 6 screws
Figure 25.2
Figure 25.3
Loosen (do not remove) 2
screws on each side and lift
off blower housing
Remove left side
panel and disconnect
blower wires
Convection Blower
& Housing
5 5 Service Parts Replacement
2. Combustion Blower
PART NUMBER: 812-4400
a. Turn down thermostat, let appliance completely cool
and then unplug appliance before servicing.
b. The convection blower is located at the bottom rear
of the appliance and is housed inside a screen box.
Remove the 2 screws facing forward in the center of
the blower chamber at the very back of the appliance.
c. If an outside air kit is installed on the appliance, these
screws attach the intake air channel piece of the
outside air kit to the appliance. Remove the 2 screws
and pull backwards on the channel and it will slide
down and away from the appliance. The air channel,
collar and outside air hose will be removed as one
piece.
d. There are 2 screws on each side of the housing.
Loosen all 4 screws, but do not remove them. Lift
the blower housing up slightly and slide towards you
(Figure 25.3).
e. Remove the left side panel by loosening 2 screws
(do not remove) and pull side panel away. Unplug
the 2 black blower wires by disconnecting the spade
connectors.
f. To remove blower from the housing, remove 2 screws
in the front of the housing and very carefully bend the
2 housing sides out and bend the back of the housing
away from the blower. This allows for room to access
the back 2 screws and nuts (4 total) that is securing
the blower to the housing.
g. Remove blower and replace with new blower.
h. Re-install in reverse order.
a. Turn down thermostat, let appliance completely cool
and then unplug appliance before servicing.
b. Remove both side curtains by loosening 2 screws (do
not remove) and pull side panels away.
c. Remove 4 screws from the back screen and pivot
the top of the screen toward you leaving the bottom
attached to appliance (Figure 25.1).
d. Remove 2 screws to remove the thermostat block
and disconnect the 2 yellow wires.
e. Remove the 2 screws from the power inlet and rotate
it through the hole and out of the screen, leaving the
wires attached.
f. Disconnect the vacuum hose and both wires (orange
and red) from the vacuum switch attached to the rear
screen.
g. Remove both wires from exhaust blower (blue and
double white).
h. Remove 6 screws using a athead screwdriver or a
1/4” nut-driver. Retain screws for use on replacement
blower (Figure 25.2).
i. Remove exhaust blower and gasket.
j. Install new gasket and blower. Discard blower housing
if not needed.
k. Re-install in reverse order.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet in the language / languages: English as an attachment in your email.

The manual is 8.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info