23 12/237021-802L
Table 23.1
With proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do
experience a problem, this troubleshooting guide will assist a qualied service person in the diagnosis of a problem and the
corrective action to be taken. This troubleshooting guide can only be used by a qualied service technician.
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Plug in appliance -
No response.
No current to outlet. Check circuit breaker at service panel.
7 amp fuse defective. Replace fuse.
#3 snap disc tripped or defective. Reset or replace snap disc.
Control box defective. Replace control box.
Call light on. No re.
No fuel in re pot.
Out of fuel. Check hopper. Fill with fuel.
#2 snap disc may be defective. Replace snap disc.
Vacuum switch not closing, no vacuum.
Check exhaust blower is plugged in and operating.
Check vacuum switch is plugged in.
Check vacuum hose is in good condition, clear and
connected at both ends.
Check thermocouple is in good condition and
plugged in properly.
Make sure venting system is clean.
Make sure front door is closed.
Control box defective. Replace control box.
Call light on. No re.
Partially burned fuel in re pot.
Fire pot clean-out plate not closed.
Check that re pot clean-out plate is fully closed.
Clean re pot. Make sure there is no clinker in the
re pot. See Cleaning Fire Pot with Cleaning Rod
& Fire Pot Scraper on page 19.
Fire pot is dirty (missed ignition). Clinkers may have to be broken up with re pot
clean-out tool or other means.
Call light on. No re.
Unburned pellets in re pot.
Fire pot clean-out plate not closed. Check that re pot clean-out plate is fully closed.
Fire pot is dirty.
The ignition hole between the igniter bracket
and re pot is blocked.
Clean re pot. Make sure there is not a clinker in the
re pot. Clinkers may have to be pushed out of re
pot with re pot clean-out tool or other means.
Scrape with solid piece of wire.
Igniter not working.
Remove ash drawer to see if igniter is glowing red
on start-up.
Check igniter wires for good connection.
Replace igniter using 1/4 inch (6mm) male /female
spade connectors.
Control box defective. Replace control box.
Slow or smoky start-up.
Fire pot clean-out plate not closed.
Fire pot is dirty.
Check that re pot clean-out is fully closed.
Clean re pot. Make sure there is not a clinker in the
re pot. Clinkers may have to pushed out of re pot
with re pot clean-out tool or other means.
Excessive amount of fuel at start-up. Reduce feed rate using feed rate adjustment control
rod located inside hopper.
Dirty exhaust and/or venting system.
Check for ash build up in appliance, including behind
rear panels, rebox, heat exchanger, exhaust blower
and venting.
No call light. Appliance does
not begin start sequence.
Thermostat not set to a high enough temperature. Adjust thermostat above room temperature.
Snap Disc #3 tripped. Reset snap disc.
No power. Connect to power.
Fuse blown. Replace fuse.
Connections at thermostat and/or appliance
not making proper contact. Check connections at thermostat and appliance.
Defective thermostat or thermostat wiring.
Replace thermostat or wiring.
NOTE: To test thermostat and wiring, use a jumper
wire at the thermostat block on the appliance to by-
pass thermostat and wiring.
Control box defective. Replace control box.
4 4 Troubleshooting Guide
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet in the language / languages: English as an attachment in your email.

The manual is 8.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info