Figure 20.1
Heat Exchanger Tubes
Cleaning Rods
Figure 20.2
Vacuum
Exhaust Area
Right Brick
Removed
NOTE: Hearth & Home Technologies recommends to
use a heavy duty vacuum cleaners specically designed
for solid fuel appliance cleaning.
9. Cleaning the Hopper
• Frequency: Monthly or after burning 50 bags of fuel or
when changing fuel type
• By: Homeowner
After burning approximately 1 ton of fuel you will need to
clean the hopper to prevent sawdust build-up.
A combination of sawdust and pellets on the auger reduces
the amount of fuel supply to the re pot. This can result in
nuisance shutdowns and mis-starts.
a. The appliance must be in complete shutdown. Allow
the appliance to completely cool down.
b. Empty the hopper of any remaining pellets.
c. Vacuum the hopper and feed tube.
8. Cleaning the Exhaust Path
• Frequency: Every 25 bags or monthly or more frequently
depending on ash build-up.
• By: Homeowner
a. Appliance must be completely cool.
b. Open cast hinge face. Remove bafe and right
brick and thoroughly vacuum the area and continue
throughout the rest of the rebox.
c. Replace right brick and bafe and close cast
hinge face.
7. Cleaning Beneath Heat Exchanger
• Frequency: Monthly or after burning 1 ton of fuel
• By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. A more thorough cleaning is needed to remove the
excess ash that is left behind from the use of the
cleaning rods for the heat exchanger tubes.
c. The ash will be resting on the back of the bafe. This
will require removing the bafe. Refer to Bafe on
page 27.
6. Cleaning Heat Exchanger Chambers & Drop Tube
• Frequency: Monthly or every 1 ton of fuel
• By: Homeowner
The amount of ash buildup in the re pot will be a good
guide to determine how often you should clean the
heat exchangers.
a. Allow the appliance to completely cool down before
pulling the cleaning rods. Turn the thermostat on and
then immediately off to start the exhaust blower on its
cycle time. It will pull y ash out the exhaust instead
of into the room.
b. Locate the 2 exposed rods directly underneath the
heat exchanger tubes (Figure 20.1).
c. To clean, pull the rods straight out until it stops,
approximately 8 inches (203mm). Slide the rods OUT
and IN a couple of times.
5. Disposal of Ashes
• Frequency: As needed
• By: Homeowner
Ashes should be placed in a steel container with a tight-
tting lid. The container of ashes should be moved outdoors
immediately and placed on a non-combustible oor or
on the ground, well away from all combustible materials,
pending nal disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled. Other
waste shall not be placed in this container.
Disposal of Ashes
Ashes should be placed in metal container
with tight tting lid.
Ashes should be retained in closed
container until all cinders have
thoroughly cooled.
WARNING
Heat exchanger cleaning rods may be
warm to the touch. For safety purposes
wear gloves.
Do not pull heat exchanger cleaning rods
while appliance is operating.
Push cleaning rods IN when done, DO
NOT leave cleaning rods OUT. Injury
can occur.
WARNING
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet in the language / languages: English as an attachment in your email.

The manual is 8.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info