11 12/237021-802L
Figure 11.3
Thumb Screw
Set Screw
Feed Adjustment
Control Rod
Increase
Decrease
J. Feed Rate Adjustment Instructions
The feed adjustment control rod is factory set, and should
be adequate for most fuels. However, if the ame height is
too high or too low, you will need to adjust the feed rate.
Wait until the appliance has been burning for 15 minutes
before making your adjustments and allow 15 minutes for
feed adjustment to take effect.
1. Loosen the set screw 1/4 to 1/2 turn during set-up
of appliance. This will allow movement of the feed
adjustment control rod. Do not re-tighten set screw
(Figure 11.3). Loosen the wing nut.
2. Adjust the feed adjustment control rod upward towards
the “+” symbol to increase the feed rate and ame
height or down towards the “-” symbol, to decrease the
feed rate and ame height.
3. Re-tighten the wing nut.
I. Fire Characteristics
A properly adjusted re with the heat output control switch
set on “high” has a short active ame pattern that extends
out of the re pot approximately 4 inches (102mm). If the
re has tall ames with black tails and seems somewhat
lazy, the feed rate will need to be reduced. This is done
by sliding the fuel adjustment control rod down, which will
reduce the feed. If the re is not 4 inches (102mm) tall, slide
the fuel adjustment control rod up to increase the feed. A
medium and low setting will give a shorter ame. The ame
will rise and fall somewhat. This is normal.
Correct Flame Size, Yellow/White in Color
Correct
Figure 11.1
Tall, Lazy Flame, Orange in Color
Incorrect
Figure 11.2
Fire Risk.
High ask fuels, or lack of maintenance, can
cause the re pot to ll with ash and clinker.
If the re pot lls to the top, immediately
shut down the appliance and clean.
Failure to do so could result in smoking,
sooting and possible hoper res.
WARNING
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet in the language / languages: English as an attachment in your email.

The manual is 8.11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet

Quadra-Fire Castile - Pellet User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info