U. Frequently Asked Questions
What causes my glass to become dirty?
If the glass has white ash build up it is normal and the glass should be cleaned. If it is a black soot build up airow through the
unit may be restricted. The most often cause is overdue maintenance and cleaning; see Maintaining and Servicing section
on page 18 and/or make adjustments to the feed rate adjustment control (reference Feed Rate Adjustment Instructions
on page 11).
How can I get more heat out of the appliance?
The most often cause of diminished heat output is overdue maintenance and cleaning; see Maintaining and Servicing
section on page 18.
What should I do if I smell smoke or there is ash/soot coming from the appliance?
While there will always be some smoke smell from wood burning appliances (including pellet) you should investigate all
venting to make sure it is sealed properly. Follow venting manufacturers recommendations for sealing pipe joints.
In addition most homes are built very tight today and with exhaust systems can create negative pressure in the home. See
Negative Pressure on page 16 in the installation manual. For ash or soot check the above and the exhaust blower housing
and seals.
Why would my appliance run ne last winter but not start this fall?
It is possible that the stove was not properly prepared for the non-burn season; see Troubleshooting Guide starting on
page 23.
Is there a place to lubricate the blowers to quiet them down?
No. The most often cause of noisy blowers is from the impellers becoming dirty over time; see Maintenance and Service
section on page 18.
What is the metal object with the bend in it that came inside the plastic bag?
It is a clean-out tool used to help clean the re pot and remove any jams in the rare event they occur in the feed tube.
Why is there a black residue building up on the outside of my home?
Wind can cause this to happen. If the appliance is oper ating correctly very little soot should ever exit the termina tion cap.
Check to be sure the venting is installed per the installation manual and local codes.
Do I need an outside air kit?
Outside air is required for mobile home installs and in some jurisdictions. Refer to Listing & Code Approvals on page 6,
Mobile Home Installation on page 27 in the installation manual and Appliance Set-up on page 21 in the installation
manual. Also refer to local building codes.
I am seeing sparks coming out of my pipe (termination cap) outside is this safe?
This is normal. As long as clearances to combustibles were followed this is safe.
I have no power to anything. Does this unit have a circuit breaker or fuse or a reset button?
This unit has one fuse on the control board and a resettable snap disc mounted to the feed tube. If the appliance overheats
then the snap disc can be reset; if the fuse is blown the control board must be replaced.
Where is the serial # located on my unit?
The serial number is riveted to appliance behind left side panel; remove the cast side and swing label forward.
No pellets are dropping in my re pot.
See troubleshooting guide.
Contact your dealer for additional information regarding operation and troubleshooting.
Visit www.quadrare.com to locate a dealer.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet - Insert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet - Insert in the language / languages: English as an attachment in your email.

The manual is 9.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet - Insert

Quadra-Fire Castile - Pellet - Insert User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info