Table 14.1
Event Time Temperature
MORN 6:00 AM 70°F (21°C)
DAY 8:00 AM 62°F (17°C)
EVE 6:00 PM 70°F (21°C)
NITE 10:00 PM 62°F (17°C)
R. Thermostat Temperature Programs
The thermostat by default has 4 separate program events
they are: MORN, DAY, EVE, and NITE. Each event ends at
the start time of the following event.
NOTE: When the last event is nished for each day or
group of days, the thermostat will advance forward into
the next day or group of days.
NOTE: If the thermostat is set for 2 events a day instead
of 4, the thermostat will only use the DAY and NITE
events.
STATIC NOTICE
Thermostat is protected against normal static electric
discharges, however to minimize the risk of damaging
the thermostat in extremely dry weather, please touch a
grounded metal object before touching the thermostat.
ITEM #08 (TEMPERATURE DIFFERENTIAL):
The thermostat works by turning your heating system on
and off whenever the room temperature varies from the
desired set-point temperature.
Use the UP/DOWN buttons to change the number value
between 1 and 9. Generally your system should cycle
on about 3 to 6 times per hour. A smaller differential
number makes the system cycle more frequently, so the
room temperature is more precise and constant. A larger
differential number will make the system remain on for a
longer duration each time and decreases the number of
cycles per hour.
Default is set to 4.
Q. Thermostat Operation Instructions
SET DAY AND TIME:
Place the Set switch into the DAY/TIME position. With the
day ashing press UP or DOWN to set the day or the week.
Press NEXT and the clock time will start ashing. Use UP or
DOWN to set the time; verify the AM/PM indicator is correct.
Return the Set switch to RUN position when nished.
HEATING:
Basic operation of the thermostat can be obtained with
the SET switch in the RUN position. The temperature
can be adjusted using the UP and DOWN buttons.
When the thermostat is rst powered on, it will follow
a default temperature routine that is preset from the
factory (Table 14.1).
TEMPERATURE HOLD:
Temperature hold is used for maintaining a xed set
temperature; once a hold is initiated, the thermostat will
maintain the set temperature indenitely. To enter a HOLD
state, press the HOLD button one time and the word HOLD
will appear on the display. To cancel, press the HOLD button
once again.
LCD DISPLAY BACK LIGHT:
The display screen is lighted to assist viewing at nighttime,
or in locations with low light levels. Press any button on the
front panel to activate the approximate 10 second back light.
TEMPERATURE OVERRIDE:
While thermostat is in RUN mode, the set temperature
can be temporarily changed by pressing UP or DOWN.
The temporarily changed set temperature will return to
the programmed value stored in memory when start time
of the next upcoming scheduled event is reached (MORN,
DAY, EVE, OR NITE). While the temporary changed set
temperature is in effect, the word OVERRIDE will be shown
on the display screen. To cancel, move TEMPERATURE
switch to OFF and back to HEAT again.
6. Use steps 3 through 5 to set up the events for the rest of
the week or group of days.
7. Return the SET switch back to RUN.
SET TEMPERATURE PROGRAMS:
1. Move Temperature switch to HEAT.
2. Move SET switch to TEMP PROG position.
3. Starting with Monday, use the UP or DOWN buttons to
adjust the start time and set temperature for the MORN
event, and then press NEXT button to advance.
4. Adjust the start time and set temperature of the DAY
event then press NEXT button.
5. Continue in this same manner to adjust the start time
and set temperatures for the EVE and NITE events
for Monday.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire Castile - Pellet - Insert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire Castile - Pellet - Insert in the language / languages: English as an attachment in your email.

The manual is 9.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire Castile - Pellet - Insert

Quadra-Fire Castile - Pellet - Insert User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info