C. General Maintenance
1. Creosote (Chimney) Cleaning
• Frequency: Every 2 months during heating season or
as recommended by a certied chimney sweep; more
frequently if chimney exceeds or is under 14-16 ft.
(measured from bottom of appliance)
• By: Certied Chimney Sweep
Remove all ash from the rebox and extinguish all hot embers
before disposal. Allow the appliance to cool completely.
Disconnect ue pipe or remove bafe and ceramic blanket
from appliance before cleaning chimney. Otherwise residue
can pile up on top of the bafe and ceramic blanket and
the appliance will not work properly. (See Bafe Removal
on page 25). Close the door tightly. The creosote or soot
should be removed with a brush specically designed for
the type of chimney in use. Clean out fallen ashes from the
rebox.
It is also recommended that before each heating season
the entire system be professionally inspected, cleaned and
repaired if necessary.
Inspection: Inspect the system at the appliance connection
and at the chimney top. Cooler surfaces tend to build
creosote deposits quicker, so it is important to check the
chimney from the top as well as from the bottom.
Formation and Need For Removal: When wood is burned
slowly, it produces tar and other organic vapors which
combine with expelled moisture to form creosote.
The creosote vapors condense in the relatively cool
chimney ue of a newly-started or a slow-burning re. As
a result, creosote residue accumulates on the ue lining.
When ignited, this creosote creates an extremely hot re
which may damage the chimney or even destroy the house.
The chimney connector and chimney should be inspected
once every 2 months during the heating season to determine
if a creosote or soot buildup has occurred. If creosote or
soot has accumulated, it should be removed to reduce the
risk of a chimney re.
3. Appliance Inspection
• Frequency: Every 2 months at the same time the
chimney and chimney connector are inspected.
• By: Homeowner
Check for:
Cracks in glass
Door handle - smooth cam operation
Bafe and ceramic blanket correct placement
Bafe for warp-age
Firebrick for cracks, broken or crumbly
Door gasket (Dollar bill test): Place a dollar bill between
the stove and the door and then shut the door. If you can
pull the dollar bill out, replace the door gasket.
Glass frame for loose screws
Ashes should be placed in a metal container with a tight
tting lid. The closed container of ashes should be placed
on a non-combustible oor or on the ground, well away
from all combustible materials, pending nal disposal. If the
ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container
until all cinders have thoroughly cooled.
2. Disposal of Ashes
• Frequency:
When ash is within 1-3/4 in. (44mm) of rebox
lip
• By: Homeowner
Fire Risk.
Prevent creosote buildup.
Inspect chimney connector and
chimney once every two months during
heating season.
Remove creosote to reduce risk of chimney
re.
Ignited creosote is extremely HOT.
WARNING
Fire Risk.
Do not use chimney cleaners or ame
colorants in your appliance. Will corrode
chimney pipe.
WARNING
Fire Risk.
Ashes could contain hot embers.
WARNING
Fire Risk. Disposal of Ashes
Ashes should be placed in metal container
with tight tting lid.
Do not place metal container on
combustible surface.
Ashes should be retained in closed
container until all cinders have
thoroughly cooled.
WARNING
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Quadra-Fire 4300 series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Quadra-Fire 4300 series in the language / languages: English as an attachment in your email.

The manual is 6.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Quadra-Fire 4300 series

Quadra-Fire 4300 series User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info