END OF SEASON OPERATIONS
To empty the internal circuit completely of water, remove the cap(fig. 32).
Run off all water left into a basin. When all the water has been drained, put the
cap back in place. Clean the filter and dry thoroughly before putting back.
L TROUBLE SHOOTING
Phenomenon Troubleshooting Solution
The appliance does
not come on
• There is no current
It is not plugged into the
mains
The internal safety device has
tripped
•Wait
• Plug into the mains
Wait 30 minutes, if the problem
persists, contact your service center
The appliance works
for a short time only
Here are bends in the air
exhaust hose
Something is preventing the
air from being dis charged
Position the air exhaust hose
correctly, keeping it as short and
free of curves as possible to avoid
bottlenecks
Check and remove any obsta-cles
obstructing air discharge
The appliance works,
but does not cool the
room
Windows, doors and/or
curtains open
Close doors, windows and curtains,
bearing in mind the “tips for
correct use” given above
There are heat sources in the
room (oven, hairdryer, ate)
• Eliminate the heat sources
The air exhaust hose is
detached from the appliance
Fit the air exhaust hose in the
housing at the back of the
appliance
The technical specification of
the appliance is not adequate
for the room in which it is
located
During operation,
there is an unpleasant
smell in the room
• Air filter clogged Clean the filter as described there is
an above
The appliance does
not operate for about
three minutes after
restarting it
The internal compressor safety
device prevents the appliance
from being restarted until
three minutes
Wait. This delay is part of normal
operation
The following
message appears on
the display:
The appliance has a self
diagnosis system to identify a
number of malfunctions
• See the SELF-DIAGNOSIS Chapter
Never attempt to disassemble or repair the device. Inexpert repairs invalidate the
guarantee and can endanger the users of the device.
M GUARANTEE CONDITIONS
The air conditioner is supplied with a 24-month guarantee, commencing on the
date of purchase. All material and manufacturing defects will be repaired or
replaced free of charge within this period. The following rules apply:
1. We expressly refuse all further damage claims, including claims for collateral
damage.
2. Repairs to or replacement of components within the guarantee period will
not result in an extension of the guarantee.
Fig. 32
4
82
82


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Qlima PH534 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Qlima PH534 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 18,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info