The main image is shown with optical magnification ratio which
corresponds to ratio x1.0.
When is turned on, you can operate the continuous PiP step-up and
digital zoom. The full optical magnification will take place only in the
dedicated window.
When PiP is turned off, the image is shown with the optical
magnification set for the PiP function.
STREAM VISION
19
HELION thermal imagers support Stream Vision technology which
allows you to stream image from the display of your thermal imager to a
smartphone or tablet PC via Wi-Fi in real time mode. You can find further
guidelines on Stream Vision online at www.pulsar-nv.com
Note: The Stream Vision application allows you to update the firmware
features of your thermal imager.
Scan the QR codes to download Stream Vision free of charge:
Google Play (Android OS): iTunes (iOS):
USB CONNECTION
20
Connect one end of the USB cable to the Micro-USB (4) port of your
device, and the other end to the USB port of your PC/laptop.
Turn the device on with a short press of the ON (11) button (device
that has been turned off cannot be detected by your computer).
Your device will be detected by the computer automatically; no drivers
need to be installed.
Two connection modes will appear
on the display:
Memory card (external memory)
and Power.
Select connection mode with UP
and DOWN buttons.
Confirm selection with a short press of the M button.
USB connection
Use as power
Use as memory card
22
21
Move the lower fixed bar under the object being ranged and, while
pressing the UP/ DOWN buttons, move the upper horizontal bar
relative to the lower fixed bar until the object fits entirely between the
two cursors. The distance to the object is automatically recalculated
as you move the upper line.
If ranging does not take place within 10 seconds, the information
disappears from the display.
To select the unit of measurement (metres or yards), go to the
respective menu option.
Before it appears on the display, a measured distance value is
rounded up to 5 m for larger values, and rounded down to 1 m for
smaller values.
Exit rangefinder mode with a short press of the M button or wait 10
seconds to exit automatically.
FUNCTION DISPLAY OFF
The Display off function deactivates transmission of image to the display
by minimizing its brightness. This prevents accidental disclosure.
The device keeps running.
17
When the device is on, hold down the ON (11) button. Display goes
out, message “Display off”.
To activate the display, press briefly the ON button.
When holding down the ON button, the display shows “Display off”
message with countdown, the device will turn off.
6.9x
3.1x
FUNCTION PiP
18
PiP (“Picture in Picture”) allows you to see
a zoomed image simultaneously with the
main image in a dedicated window.
Turn on/off the PiP function with a long press of the DOWN (8) button.
Change zoom ratio in the PiP window with a short press of the DOWN
button.
The zoomed image is displayed in a dedicated window, with the full
optical magnification being shown.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pulsar Helion XQ50F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pulsar Helion XQ50F in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 5,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info