730040
11
Zoom out
Zoom in
Previous page
1/84
Next page
15
16
= Wi-Fi off (default password)
= Digital zoom off
= PiP off
= Colour palette White Hot
= Unit of measurement - metric
Warning: date and time settings, default pixel map
and remote control activation are not restored.
Lens
selection
Lens selection is used when replacing objective
lenses for the models: HELION XP28; HELION
XP38; HELION XP50.
Selection of the lens type is important for the correct
display of the optical magnification and adequate
operation of the Stadiametric rangefinder.
= Replace the objective lens: to do this, move the
latch (13) backwards, turn the lens counter-
clockwise all the way and remove the lens.
= Install a new lens, move the latch backwards and
move clockwise until the latch snaps.
= Enter the submenu with a short press of the M
button.
= With a short press of the UP/ DOWN buttons
select the desired lens: 28; 38 or 50.
= Confirm selection with a long press of the M
button.
= Enter the submenu with a short press of the M
button.
= Select icon with a short press of the M button.
= A marker (H) appears on the left side of the
display.
= On the right side of the display appears
“magnifying glass” (G)a magnified image in a
frame with a fixed cross , designed for easier
detection of a defective pixel and to match the
pixel with the marker, horizontal and vertical
arrows for X and Y axes (I) showing marker's
movement.
+
The defective pixels on the sensor may proportionally increase in size
when digital zoom is activated. HELION thermal imagers allow the user
to repair defective pixels on the detector using a software-based method
or to abort deletion.
G
H
I
x=95
y=99
Reset
Restore default settings
= Enter the Reset submenu with a short press of the
M (9) button.
= With a short press of the UP/ DOWN buttons
select “Yes” to restore default settings or “No” to
abort.
= Confirm selection with a short press of the M
button.
= If “Yes” is selected, display will show “Return
default settings?” and “Yes” and “No” options.
Select “Yes” to restore default settings.
= If “No” is selected, action is aborted and you
return to the submenu.
The following settings will be restored to their
original values before changes made by the user:
= Operating mode of video recorder video
= Operating mode Forest
= Calibration mode automatic
= Language English
Defective
pixel repair
Defective pixel repair
When operating a thermal imager, defective (dead)
pixels (bright or dark dots with constant brightness)
may become visible on the sensor.
= Hold down the M (9) button to enter the main
menu.
= Select submenu with UP (8) and DOWN (10)
buttons.
= Press briefly the M button the enter the submenu.
= Turn the microphone on/off with a short press of
the M button.
= With the microphone on, you will have audio track
in your video. Microphone is off by default.
Microphone
Off
Remote
Control
Remote control (bought separately)
Before operating the remote control (RC),
remember to activate it as follows:
= Press the M button, countdown starts (30 sec),
within which hold down for two seconds any RC
button.
= If activation is successful, the message
«Connection complete» appears .
= If error occurs the message «Connection failed»
appears . Repeat the procedure.
= The RC is activated and ready for use.
= To unlink the RC, press the М button, wait for the
countdown to expire without pressing any RC
button for 30 sec.
= All remote controls previously linked to your sight
are now unlinked.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pulsar Helion XQ38F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pulsar Helion XQ38F in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 5,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info