Tekniske data N
VCP 700 E-L VCP 700 E-M
Nettspenning 230 V – 240 V 230 V
Nettfrekvens 50/60 Hz 50/60 Hz
Nettsikring EU – 16 A 16 A
CH/DK – 10 A
AUS – 10 A
Effektopptak 1200 W 1200 W
Tilkoplingsverdi for apparatstikkontakt EU – 2400 W 2400 W
CH/DK – 1100 W
AUS – 1200 W
Total tilkoplingsverdi EU – 3600 W 3600 W
CH/DK – 2300 W
AUS – 2400 W
Luft-volumstrøm (max.) 3600 l/min 3600 l/min
Undertrykk (max.) 23 000 Pa 23 000 Pa
Måleflate-lydtrykknivå fra 1 m avstand, EN 60704-1 60 dB (A) 60 dB (A)
Arbeidsstøy 57 dB (A) 57 dB (A)
Nettilkoplingsledning: lengde 7,5 m 7,5 m
type EU – H05 RR-F 3G1,5 H05 RR-F 3G1,5
CH/DK – H05 RR-F 3G1,0
AUS – H05 RR-F 3G1,5
Beskyttelsesklasse I I
Beskyttelsestype IP X4 IP X4
Radiostøydempingsgrad EN 55014-1 EN 55014-1
Beholdervolum 70 l 70 l
Bredde × dybde × høyde 580 × 605 × 970 mm 580 × 605 × 970 mm
Vekt 27 kg 27 kg
Sugeslange – Minimum Tilhørende undertrykk ved
luft-volumstrøm overgang sugeslange/verktøy
27 mm 690 l/min 16 300 Pa
32 mm 970 l/min 15 700 Pa
36 mm 1220 l/min 14 200 Pa
50 mm 2360 l/min 7800 Pa
Tilbehør VCP 700 E-L VCP 700 E-M
Betegnelse Bestillings-nr. Bestillings-nr.
Filterpose (5 stykker) 632 735 632 735
Avfallspose (5 stykker) 632 737 632 737
Filterelement 626 437 626 437
Betjeningselementer
1. Håndtak
2. Håndtak for forlengelsesrøret
3. Håndtak for tilbehøret
4. Bryter med regulering av sugekraften
5. Lukkeklemme
6. Avfallskar
8. Inngangsfitting
9. Stikkontakt
10. Håndtak for kabelen
12. Karsperring
13. Hjul med bremse
14. Innstilling av rørdiameter (VCP 700 E-M)
Prøver og godkjennelser
Sugerne er testet i henhold til IEC/EN 60335-2-69
inklusive vedlegg AA. Oppfyllelse av alle krav som
stilles til apparater i støvklasse (L/M) er fastslått.
Kontroller i henhold til de nasjonale ulykkesfore-
byggelsesforskrifter skal utføres regelmessig.
Minimum en gang årlig skal produsenten eller en
instruert person utføre en støvteknisk kontroll, f. eks.
med hensyn til skader på filteret, maskinens tetthet
og kontrollinnretningenes funksjonsdyktighet.
79


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Protool VCP700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Protool VCP700 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 20,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info