9.1 Changing the lter element
NOTE
Motor damage
Never operate the extractor without a l-
ter element tted as the motor may be-
come damaged.
Open the locking clips [2-2] and remove the
top section of the machine [2-1].
Turn the top section of the machine so that
the main lter is facing upwards (Fig. [7]).
Fold over the lever [7-3] and remove the
retainer [7-2].
Remove the used main lter and replace
[7-1] with a new one.
Dispose of the used lter in accordance with
statutory regulations.
Remove any dust which has fallen behind
the main lter when it is replaced.
Insert the retainer [7-2] and fold over the
lever [7-3] until it engages.
Replace the top section [2-1] and close the
locking clips [1-11].
9.2 Emptying the dust container
The dust container [2-3] can be emptied
once the top section has been removed.
After extracting uids, clean the ll level
sensors [9-1] regularly with a soft cloth
and inspect for damage.
10 Accessories
Use only original PROTOOL accessories and
PROTOOL consumable material intended for
this machine because these components
are designed speci cally for the machine.
Using accessories and consumable mate-
rial from other suppliers will most likely af-
fect the quality of your working results and
limit any warranty claims. Machine wear or
your own personal workload may increase
depending on the application. Protect your-
self and your machine, and preserve your
warranty claims by always using original
PROTOOL accessories and PROTOOL con-
sumable material!
The order numbers for the accessories and
lters can be found in the PROTOOL catalogue
or on the Internet at “www.protool.com”.
10.1 Module slot
To extend the vacuum cleaner, there are the
following module in the accessory range,
that can be tted to the module slot [1-2]
by an authorised customer service work-
shop:
- Socket module with permanent power
supply.
10.2 Systainer depot
The surface of the vacuum cleaner is used
as a systainer parking zone:
The systainer can be hooked easily into the
systainer holder – see gure [10 a].
If you wish to rmly attach the systainer to
the vacuum cleaner, you must use 4 screws
to fasten a systainer adapter to the upper
section – see gure [10 b].
11 Environmental
Protection / Disposal
Power tools, accessories and packaging
should be sorted for environmental-friendly
recycling.
Only for EC countries:
Do not dispose of power tools into
household waste!
According to the European Directive
2002/96/EC on waste electrical and elec-
tronic equipment and its incorporation into
national law, power tools that are no longer
suitable for use must be separately collect-
ed and sent for recovery in an environmen-
tal-friendly manner.
REACh
REACh is a European Chemical Directive
that came into effect in 2007. As “down-
stream users” and product manufacturers,
we are aware of our duty to provide our
customers with information. We have set up
the following website to keep you updated
with all the latest news and provide you
with information on all the materials used
in our existing products:
http://www.tts-protool.com/reach
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Protool VCP 260 E M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Protool VCP 260 E M in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 10,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info