Only use milling rings recommended by
the manufacturer.
The machine is only allowed be used
when protective guard is in place and
additional handle is fastened.
Plug in the exible power supply cable’s
plug into the wall socket when the ma-
chine is off.
Make yourself sure whether the material
that is going to be machined does not
contain electric, water or gas lines – an
injury could occur.
Do not mill over metal objects, nails or
screws.
The machine is not allowed to be operat-
ed by a person under 16 years of age.
5.8 Noise/Vibration Information
CAUTION
The noise created during work may
damage hearing.
Use hearing-protective aids!
Measured values determined according to
EN 60 745.
Typically the A-weighted noise level of the
tool are:
Sound pressure level: 89 dB (A).
Sound power level: 100 dB (A).
Inaccuracy of measurement K = 3 dB (A).
The typical weighted acceleration is 3 m/s
2
.
Inaccuracy of measurement K = 1.5 m/s
2
.
6 Activation
WARNING
Risk of injury, if the tools are used
with wrong supply power.
Check that the information on the manufac-
turing label complies with the actual power
supply voltage.
Check that the plug type is the same as the
socket type.
Tools designed for 230 V may be connected
to 220 V / 240 V power supply.
6.1 Switching on – off
Switching on
Move the switch button [1-2] forward and
the device will switch on. If you press the
front part of the button, it will arrest and
start continual operation.
Switching off
Press the rear part of the button [1-2] to re-
lax arrest. The button returns to switched-
off position.
6.2 Motor electronics
Starting current limitation
Electronically controlled continual running
secures device acceleration without back
thrust. Due to starting current limitation in
the device, 15A protection is suf cient.
WARNING
Devices without starting current limi-
tation need higher protection – at
least 16A circuit breaker.
Switching off during back thrust
During sudden drop of revolutions, for ex-
ample blocking in dividing cut, the current
input in motor stops. For re-starting, the
device must be rst switched off and again
switched on.
Protection against re-starting
Prevent uncontrolled starting of the device
after current supply cut off. For re-starting,
the device must be rst switched off and
again switched on.
Revolutions pre-setting
Use the revolutions regulator [1-3] for
smooth revolutions pre-setting.
Degree 1: 2000 min
–1
Degree 4: 4500 min
–1
Degree 2: 2950 min
–1
Degree 5: 5300 min
–1
Degree 3: 3750 min
–1
Degree 6: 5900 min
–1
Required number of revolutions depends on
applied grinding wheel and worked mate-
rial.
Constant electronics
Constant electronics maintains revolutions
during operation and idle run near the con-
stant. Regular operating shift is achieved.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Protool RGP 80-11 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Protool RGP 80-11 E in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info