490692
14
Zoom out
Zoom in
Previous page
1/88
Next page
14
Operating with electric generator (EG) with
combustion motor drive
NOTE
The manufacturer of the stirrer does not pro-
vide any guarantee for incorrect operation of
the stirrer with any EG.
The stirrer can be operated with an EG if the fol-
lowing conditions are met:
- The output voltage of the EG must always be
within the range of 230 VAC ±10%, the EG must
be equipped with Automatic Voltage Regula-
tion (AVR). The stirrer must not work correctly
without this regulation and may also become
damage.
- The power of the EG must be at least 2.5 times
greater than the connected load of the stir-
rer (i.e. 2.5 kW for MXP 1000/1002, 3 kW for
MXP 1200)
- If you operate using an EG that does not have
suf cient power, the speed may uctuate and
the power of the machine may decrease
6.8 Stationary use
The stirrer can be clamped into the MSP 57 PRO-
TOOL stirrer stands at the 57 mm collar [1-6].
6.9 Suction
CAUTION
Inhaling the dust may damage the respira-
tory tract.
When working with dust, you must wear res-
piratory protection and connect the machine
to the suction attachment.
To extract dust from the mixing container, you can
connect it to the PROTOOL MXP suction attach-
ment.
7 Service and maintenance
CAUTION
Never use a machine that is damaged in any
way! (Damage also includes a ripped or worn
exible switch protection or clamping ring
protection on the ErgoFix adapter).
Have a damaged machine repaired in an au-
thorised PROTOOL workshop.
- To ensure safety against an accident caused by
electrical current and to retain the protection
level, this work must be carried out in an elec-
trical engineering workshop that is authorised
to carry out such repairs.
- The ventilation holes on the motor hood must
not be blocked.
- The machine automatically switches off if the
carbon brushes are worn. The machine must
be sent to the workshop for maintenance work
(see the supplied list).
- We recommend that you clean the machine reg-
ularly. Remove any dust, residual mixing mate-
rial and any other dirt. If you use solvent-based
cleaning agents, these may damage the painted
surfaces or the plastic parts. If you use these
cleaning agents, we recommend that you test
the effect of these agents on a small, concealed
area. The ventilation holes on the motor hood
must not be blocked.
- Commission an authorised workshop to
change brushes, the power cable etc.. If
the machine is knocked in any way, it is also
necessary to entrust an authorised workshop
in order to prevent any mechanical or electrical
danger arising.
- The packaged machine can be stored in a dry
place without heating as long as the inside tem-
perature does not fall below 5 °C. The unpack-
aged machine must only be stored in a dry,
enclosed space where the temperature does not
fall below +5 °C and where no extreme tem-
perature uctuations occur.
8 Service
See enclosed sheet.
9 Environmental
Protection / Disposal
Power tools, accessories and packaging should be
sorted for environmental-friendly recycling.
Only for EC countries:
Do not dispose of power tools into house-
hold waste!
According to the European Directive 2002/96/EC
on waste electrical and electronic equipment and
its incorporation into national law, power tools that
are no longer suitable for use must be separately
collected and sent for recovery in an environmen-
tal-friendly manner.
REACh
REACh is a European Chemical Directive that
came into effect in 2007. As “downstream users”
and product manufacturers, we are aware of our
duty to provide our customers with information.
We have set up the following website to keep you
updated with all the latest news and provide you
with information on all the materials used in our
existing products:
http://www.tts-protool.com/reach
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Protool MXP 1002 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Protool MXP 1002 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 12,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info