Read this first
Note:
Please consult enclosed
tanning schedule for
advised tanning times.
Repairs may only be
carried out by qualified
personnel. Always dis-
connect the main power
at the circuit breaker
before servicing or
repairing the unit.
1 Contact ProSun Tanning International
immediately if this unit does not func-
tion as outlined in this manual.
800-874-2776
or tr CSV. 800-501-8485
2 Do not operate this unit in a moisty or
humid space.
3 Always make sure the fuses can
carry the load
4 Always disconnect the power to the
unit at the wall breaker when servic-
ing or cleaning the in-side construc-
tion of the cabine. Maintenance for
which the procedure is not described
in this manual should only be done
by a qualified electrician. Never
clean the electrical components with
fluids.
5 Ensure that the canopy when opened
does not touch the wall. This will pre-
vent damage.
6 Avoid having the acrylic sheets come
into contact with sharp objects.
7 This unit may not be operated if:
the user is not wearing protective
uv-goggles
the blue or white facial glass is
cracked or broken
the acrylic panel in the canopy and/
or bench is not present
one or more of the fans in the unit
are not functioning properly
the timing mechanism is not func-
tioning properly
the temperature inside the cabin is
96°F or higher
8 To ensure maximum tanning effec-
tiveness, change the acrylic sheet
after every 1200 hours of operation.
9 To ensure maximum tanning effec-
tiveness, replace the lamps and the
facial tanning lamps like indicated by
the manufacturer.
10 Check the environment regulations
of your respective state with regard
to the proper manner in which the
lamps are to be disposed of.
11 Note: only a special acrylic cleaner
may be used to clean the acrylic
sheet. Never use cleaners that con-
tain alcohol, as these can damage
the acrylic sheet.
12 The UV-type of the tanning unit is
indicated on the specification
sticker.
13 Ultraviolet radiation from the sun
or UV appliances can cause skin
or eye damage. These biological
effects depend upon the quality
and quantity of the radiation as
well as the skin and eye sensitivity
of the individual.
14 The skin may develop sunburn
after an excessive exposure.
Excessively repeated exposures to
ultraviolet radiation from the sun or
UV appliances may lead to prema-
ture ageing of het skin as well as
increased risk of development of the
skin tumours.
15 The unprotected eye may develop
surface inflammation and in some
cases, after a cataract operation
for example, damage may accur
to the retina after eccessive expo
sure. Cataracts may develop after
many repeated exposures.
16 If the supply cord is damaged, it
must be replaced by the manu
facturer or its service agent or a
similarly qualified person in order
to avoid a hazard.
17 Exchanging lamps and starters;
remove the lamp by turning this a
quarter turn to the left. Remove the
starters by turning these a quarter
turn to the left. Placement of lamps
and starters in opposite order.
18 When installing the equipment,
keep in mind the prescribed mini
mum distances as described in the
“Dimensions / Placement” chapter.
19 Clean the dust filters after every
50 hours of use. Regularly check
the dust filters.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Prosun X5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Prosun X5 in the language / languages: English as an attachment in your email.

The manual is 3,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info