791716
226
Zoom out
Zoom in
Previous page
1/276
Next page
June 2022 216 Chapter 11: SPECIFICATIONS RANGER Neo Lite / +
DVB-S2
DSS
Measurements Power, CBER, MER, C/N and Link
Margin
Displayed Data Numeric and level bar
Symbol Rate 1 - 45 Mbauds
Roll-off (α) factor of Nyquist filter 0.35 Auto
Code rate 1/2, 2/3, 3/4, 5/6, 7/8
Spectral Inversion ON, OFF
Tuning Range 250 – 2350 MHz From 2150 to 2350 MHz does not
meet sensitivity specifications
Parameter Value Additional Data
Modulation QPSK, 8PSK, 16APSK, 32APSK Compatible with CCM, ACM and VCM
modes
Margin of Power Measurement 35 dBμV - 115 dBμV2150 MHz, 27500 kSps, CR=2/3
Roll-off: 0,20
QPSK Sensitivity (QEF): 26 dBμV
8PSK Sensitivity (QEF): 30 dBμV
8PSK:
24 dBμV a 2.15 GHz / 2 MSs;
34 dBμV a 2.15 GHz / 27 MSs
Measurements Power, CBER, LBER, MER, C/N, BCH
ESR, Wrong Packets and Link Margin
Displayed Data Numeric and level bar
Symbol Rate 2 - 45 MSps QPSK, 8PSK, 16APSK, 32APSK
Roll-off (α) factor of Nyquist filter 0.20, 0.25 and 0.35
Code rate (8PSK) 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
Code rate (QPSK) 3/5, 2/3, 3/4, 5/6, 8/9, 9/10
Code rate (16APSK) 2/3, 3/4, 4/5, 5/6, 8/9, 9/10
Code rate (32APSK) 3/4, 4/5, 5/6, 8/9, 9/10
Spectral Inversion ON, OFF Auto
Pilots Indicator
TS clock Available Warning message when the TS clock
is too high
Tuning Range 250 – 2350 MHz From 2150 to 2350 MHz does not
meet sensitivity specifications
Parameter Value Additional Data
Modulation QPSK
Margin of Power Measurement 35 dBμV - 115 dBμV
Measurements Power, CBER, VBER, MER, C/N and
Noise Margin
Displayed Data Numeric and level bar
Symbol Rate 20 Mbauds or variable Auto detected
Roll-off (α) factor of Nyquist filter 0.2
Code rate 1/2, 2/3, 6/7 and AUTO
Spectral Inversion ON, OFF Auto
Parameter Value Additional Data
226


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PROmax Ranger Neo Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PROmax Ranger Neo Plus in the language / languages: English as an attachment in your email.

The manual is 11.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info