June 2022 98 Chapter 5: TOOLS
The Attenuation Test function allows the user to easily check the response of the
telecommunications installations before antennas and headers are working. It
allows the user to evaluate the response along the complete range of
frequencies by measuring the losses (attenuation) in the distribution of TV
signals, comparing reference levels at headend output and at each house
antenna plugs.
Attenuation test function is available for all signals.
1 In Settings select the terrestrial or satellite band.
2 Press the Tools key .
3 Select the Attenuation Test option.
4 The Attenuation Test function for the signal appears on screen.
5 First, set the parameters before the test, pressing the Advanced key.
Parameters to set are: Frequencies of pilot signals (pilot 0, pilot 1 and pilot
2), maximum attenuation and threshold attenuation (for more details refer
to next section).
6 Then it is necessary to Set References. This requires a signal generator. We
recommend to use of one of the PROMAX signal generators: RP-050, RP-
080, RP-110 or RP-250 (depending on the frequency band).
7 Connect the generator and the meter where the origin of the signal
distribution is in the installation (antenna, headend, etc.) or connect the
generator directly to the RF input of the meter. If necessary, the meter can
feed the generator using the Supply Output option from the Settings menu
.
8 Active the signal generator and in the equipment, press the Set Reference
key .
9 Once are set the references for the pilot signals, let the signal generator
connected to the source point of the distribution system and take
measurements in each user access point with the equipment.
10 In each measurement a message over each pilot signal indicates whether
the measure "Pass" or "Fail" according to the parameters set.
5.8 Attenuation Test
5.8.1 Description
Attenuation test
S
C
A
N
5.8.2 Operation
108


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PROmax Ranger Neo Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PROmax Ranger Neo Plus in the language / languages: English as an attachment in your email.

The manual is 11.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info