June 2022 40 Chapter 3: SETTINGS AND PREFERENCES
In the External supply voltage option the power supplier to the external units is
the power supplier of the antenna preamplifiers (terrestrial television) or the
satellite TV receiver (collective or domestic).
LNB Drain (available for terrestrial and satellite band)
The LNB drain option shows the voltage and current flowing to the external unit.
The DRAIN LNB light indicator* is lit if current is flowing to the external unit.
If there is any problems (e.g. short circuit), an error message appears on the
screen ('SHORTCIRCUIT'), a warning beep sounds. The equipment allows you to
disable the output tension that feeds the LNB when the short-circuit warning is
displayed.
The equipment does not return to its normal operating state until the problem
is solved. During this time the equipment checks every three seconds if there
still the problem, warning with an audible signal.
DiSEqC Mode (only available for satellite band)
It enables or disables DiSEqC mode. DiSEqC (Digital Satellite Equipment
Control) is a communication protocol between the satellite receiver and
accessories of the satellite system (for more details refer to CONNECTING TO
EXTERNAL DEVICES” on page 197).
SCD/EN50494 (only available for satellite band)
It enables or disables the SCD/EN50494 function to control devices of a satellite
TV installation that supports this technology (for more details refer to
CONNECTING TO EXTERNAL DEVICES” on page 197).
SCD2/EN50607 (only available for satellite band)
It enables or disables SCD2/EN50607 mode to control devices in a satellite TV
installation which must be compatible with this technology (for more details
refer to CONNECTING TO EXTERNAL DEVICES” on page 197).
Polarization (only available for satellite band)
It allows the user to select the signal polarization between Vertical/Right
(vertical and circular clockwise) and Horizontal/Left (horizontal and circular anti-
*. only available for RANGER
Neo
+
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PROmax Ranger Neo Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PROmax Ranger Neo Plus in the language / languages: English as an attachment in your email.

The manual is 11.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info