June 2022 311 Chapter iii: ADVANCED FM OPTION
2 Measurements:
•Frequency: It is the selected threshold for MPX FM deviation.
•Samples: Percentage of MPX FM deviation samples that are equal to the
selected threshold (yellow graph).
•Accumulated: Percentage of MPX FM deviation samples that are equal o
higher than the selected threshold (green graph).
3 Selected threshold for the MPX FM deviation (tipically 75 kHz). Move right-
left to change threshold.
4 .Green graph: Percentage of accumulated samples values for MPX FM
deviation (measured according to the selected standard).
5 Yellow graph: Percentage of MPX FM deviation values (measured according
to the selected standard).
Joystick Functions:
•Joystick right/left: Move cursor to select threshold for MPX FM deviation.
Function keys:
•F1 Tuning: Tuning options.
•F2 FM: FM demodulation parameters.
•F3 Tools: Tools available for FM.
•F4 Advanced: Advanced Menu.
Advanced Menu :
•Samples Hold:
-All: It takes samples continuously.
-Time: It takes samples for a period of time.
•Time: Select the period of time to take samples.
•Standard:
-All samples: Histogram calculated according to the ITU-R SM 1268-4
standard. It accumulates all values of frequency deviation into the
histogram.
-Max 50 ms: Histogram calculated according to the ITU-R SM 1268-2
standard. It measures the maxim value of frequency deviation in 50 ms
and then accumulate them into the histogram.
•Reset: It clears and re-starts the histogram.
The Datalogger function stores automatically measurements in a file set by the
user (name, channel plan). User can store for each datalogger measurements
taken at different test points of the selected installation. Measurements are
made for all channels in the active channel plan, both analogue and digital. Each
installation has its own datalogger files.
Specific measurements for FM (FM Level, Multiplex FM Level and deviation) are
also stored.
iii.3.3 Datalogger
323


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PROmax Ranger Neo 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PROmax Ranger Neo 4 in the language / languages: English as an attachment in your email.

The manual is 16.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info