PLI-143 LAMP WITH ENERGY-SAVING LIGHT 23W UK - 1
PLI-149 LAMP WITH 2 ENERGY-SAVING LIGHTS 23W
We thank you for the purchase of this Profile product.
Note: It is important that you read this manual carefully
before using the product and be sure to save this
manual for possible use later.
Note
Check if building regulations apply to your area
whereby you must have the lamp installed by an
accredited electrician. An electrician can give you
information about correct wiring. Never install the fitting
outside in rainy weather.
SWITCH OFF THE POWER BEFORE YOU INSTALL
THE LAMP.
Correct installation
With installation outside preferably choose a place
under a roof. Pay attention to the recommandations
in fig. 2
Connect the lamp to a circuit with wall switch.
Unscrew the stainless steel bolts (fig 1.1) on the side
to take the holder (fig 1.3) from the fitting.
Fix the holder to the wall with 2 screws. (fig 1.2)
Fix the lamp back on the assembled holder and
adjust the light direction as you prefer.
Remove the cover of the cable connection (fig 3.4).
Untie the nut (fig 3.5) and the additional attachment
(fig 3.6) and pull the power supply wires through the
opening with the rubber packing. (fig 3.7)
The lamp must be connected to mains voltage of
230V, max. fusing 16A.
Connect the wires according to figure 4.
Fix the cable connection cover, the nut and the
additional attachment.
Remove the protection glass in front (gif 3.8) and
insert the included bulb. Then fix the glass again.
Always respect the instructions on the identification
label of the connected power cables.
Other uses than described above can cause damage
to the product and increase the risk of short-circuit,
fire, electric shocks, etc.
The product may not be adapted as a whole. The
safety instructions must be strictly observed.
Safety instructions
The importer accepts no responsibility for damage
claims with respect to objects or persons that result
from incorrect use or non-compliance with the safety
instructions. Any damage claims in such cases will
be declared null and void.
When replacing the energy-saving bulb:
o the power supply must be switched
off.
o Do not exceed the maximum wattage
of 32W.
o Let the floodlight cool down
Always replace cracked or broken glass by glass
with the same properties as the original glass.
Technical information
Working voltage: 220-240V~50Hz
Maximum lamp power:
o PLI-143: 23W.
o PLI145: 2x23W
Maximum current strength: 10/16A.
Dustproof and splashproof: IP44.
Maintenance
Only use a dry, soft cloth for cleaning the lamp. And
make sure that the lamp has first cooled.
Never immerse the lamp in water.
Maintenance and repairs may only be carried out by
technicians who are familiar with any applicable
regulations.
Guarantee
conditions
The guarantee period for PLI-143 / PLI-149 amounts
to 2 years and commences on the date of purchase.
During the guarantee period ELTRA nv will repair any
defects attributable to material or production faults.
ELTRA NV may choose to either repair or replace a
defective appliance.
ELTRA NV is not obliged to repair or replace
appliances if they have become defective as a result of
damage, inappropriate use, or modifications or
adaptations made after the purchase date.
Take any defective appliance together with the original
receipt back to the shop where the appliance was sold.
Always add a note with a description of the problem.
Damage
ELTRA NV can under no circumstances whatsoever
be held responsible for damage of whatever nature if
the appliance was not correctly installed according to
the specified installation instructions, nor for damage
as a result of unforeseen circumstances such as
natural disasters, lightening strike, etc. All such
resulting costs are consequently at the expense of the
buyer and are not covered by the guarantee
conditions.
www.profile.eu
Eltra nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
Eltra DIYeuronet, Frontstraat 14, 5405 AM Uden,
THE NETHERLANDS
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Profile PLI-149 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Profile PLI-149 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info