Air purifier Floccus EN - 1
PCL-500
We thank you for the purchase of this Profile product.
Note: It is important that you read this manual before
using the product Then keep this manual in a safe place.
Technical information
Battery powered: 4xC excl. (6V)
Dimensions: 130 x 65 x 80.
Weight: 190g.
Battery indicator
Power consumption: 0.5W
Active oxygen output: <
0.08 ppm
Usable volume: 250 litres.
Cycle repeat: every 2 hours.
Functions fully electronically
Functions based on the ionising principle
Silent
Standing model
Functions
This appliance is highly suitable for freshening up
toilets, cupboards and particularly refrigerators.
Sterilising function
: fills the refrigerator/cupboard with
O
3
(ozone) so bacteria and fungi are removed from the
air. Foodstuffs stay fresh longer as a result.
Refreshing function
: quickly removes unpleasant
odours.
The appliance works fully automatically. When the
appliance is working the LED will continuous light up.
When the air is sufficiently clean the appliance
switches to stand-by and the LED flashes every 15
seconds. This cycle repeats itself after 2 hours.
If a red light flashes you must replace the batteries.
When the green light is flashing the batteries are still
sufficiently charged.
Installation
Unscrew the base of the appliance and insert 4
batteries (6V 4XC) in the compartment. Note the
battery polarity.
On the back of the air cleaner there is a button with
which you can switch the appliance off or set the
position (high/low). Choose ‘high mode’ when
unpleasant odours must be removed or when the
volume of the refrigerator is greater than 250 litres.
Sterilisation then takes place in 4 minutes (high)
instead of 2 minutes (low).
Always place the air cleaner on the highest shelf in the
refrigerator. Because O
3
is heavier than air it will sink
to the bottom of the refrigerator/cupboard.
NOTE
: If you place the air cleaner in your refrigerator
remember condensation. Only take the appliance out
of the refrigerator to replace the batteries.
Also always allow the air cleaner to come to room
temperature before replacing the batteries. This
enhances the life of your batteries and air cleaner
because you prevent condensation moisture from
forming in the battery compartment.
Remark
Do not place the appliance in a humid place.
Do not expose the appliance to high temperatures.
Do not allow the appliance to fall.
If you do not use the appliance for a longer period
always remove the batteries
The filter in the appliance does not have to be
replaced.
Guarantee
The guarantee period for the PCL-500 amounts to 2
years and commences on the date of purchase. During
the guarantee period Eltra NV will repair any defects
attributable to material or production faults. Eltra NV
may choose to either repair or replace a defective
appliance.
ELTRA NV is not obliged to repair or replace
appliances if they have become defective as a result of
damage, inappropriate use, or modifications or
adaptations made after the purchase date.
Bring the defective appliance, together with the
original receipt, back to the shop where the appliance
was bought. Always add a note with a description of
the problem.
Damage
ELTRA NV can under no circumstances whatsoever
be held responsible for damage of whatever nature if
the appliance was not correctly installed according to
the specified installation instructions, nor for damage
as a result of unforeseen circumstances such as
natural disasters, lightening strike, etc. All such
resulting costs are consequently at the expense of the
buyer and are not covered by the guarantee
conditions.
www.profile.eu
Eltra nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
Eltra DIYeuronet, Frontstraat 14, 5405 AM Uden,
THE NETHERLANDS
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Profile PCL-500 Floccus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Profile PCL-500 Floccus in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info