730641
5
Zoom out
Zoom in
Previous page
1/8
Next page
211000008
5 Keys : SET - C/F - DOWN/CH - RF ALARM - SNZ/LIGHT
RCC reception from: DCF
Barometric pressure display
Weather forecast: Sunny, Partly sunny, Cloudy, Rainy and Stormy
Low Battery indicator for outdoor sensor and station
Time,date and week display
Temperature in °C/°F
Indoor temperature (0°C~50°C)
Outdoor temperature (-40°C~60°C)
Indoor humidity (20%-99%)
Outdoor humidity((20%-99%))
Outdoor/indoor temperature and humidity trend
Moon phase display
Alarm and Snooze
Summertime setting
LED back light
Functions
A. START OR RESET
Default time : 2013.01.01 00:00
Default temperature °C
Barometer unit : Hpa
Weather station : partly sunny
DST : ON
The LCD display lights up for 3 seconds when changing new battery or reset-
ting, then with a sound BI the display turns into normal state, after testing
temperature and barometer, and receiving RF for 3 minutes:Then enters in
to RCC reception mode.
B. TIME SETTINGS
In the time display mode Press “SET” for 2 seconds to enter time setting :
Press “SET” to navigate between settings :
Time zone - 12/24HR - Hour - Minute - Year - Month - Day - Barometer - Exit
Press “UP/RCC” once to go ahead one step; press and hold for 2 seconds, go
ahead 8 steps/seconds speed.
Press “DOWN/CH” once to go back one step, press and hold for 2 seconds, go
back 8 steps/seconds speed.
Info :
The pascal (symbol: Pa) is the SI derived unit of pressure, and is defined as one
newton per square meter.[1]
Common multiple units of the pascal are the hectopascal (1 hPa = 100 Pa) which is
equal to one millibar,
Inches of mercury, (inHg and "Hg) is a unit of measurement for pressure. It is still
used for barometric pressure in weather reports, refrigeration and aviation in the
United States.
It is defined as the pressure exerted by a circular column of mercury of 1 inch in
height at 32 °F (0 °C) at the standard acceleration of gravity : 1 inHg = 3386.389 Pa
at 0 °C.
C. ALARM SETTINGS
At standard mode : press ALARM” swift to enter alarm mode
The ALM” will display on the position of weekday .
At ALARM” mode : press ALARM” the alarm icon will appear or disappear (alarm
ON/OFF)
Hold ALARM” enter to alarm setting , the hours starts twinkling
Press ALARM to navigate between settings : hour - minute - exit
Press “UP/RCC” once to go ahead one step; press and hold for 2 seconds, go ahead
8 steps/seconds speed.
Press “DOWN/CH” once to go back one step, press and hold for 2 seconds, go back
8 steps/seconds speed.
After setting : press ALARM” to confirm or do not touch any key for 10s to exit
settings
D. ALARM AND SNOOZE
Default time : am 7:00
With a sound BIBI for 2 minutes ,when setting alarm time is coming
When alarm sounds , press SNZ/LIGHT” to active snooze :the clock will start
beeping again after 10 minutes.
No matter on alarm mode or snooze , press any key except SNZ/LIGHT to exit
and return to normal time mode.
E. INDOOR TEMPERATURE
Temperature range 0°C/32°F +50°C/122°F
Testing cycle : 30 seconds
Temperature resolution +/- 1°C
When the current temperature exceeds the maximum temperature ,it will
show maximum temperature
When the current temperature is lower than the minimum temperature, it
will show the minimum temperature .
When ALRM/RCC/RF the clock will stop checking temperature until ALARM/
RCC/RF stops
Temperature trend
Temperature rise of 1°C/2°F,arrow upward
Temperature drop 1°C/2°F,arrow down
Temperature changes in the scope of 1°C/2°F, arrow displays horizontal.
Temperature compared at the current date and the date before 3 hours,
the clock records data every 30 minutes
F. OUTDOOR TEMPERATURE
Temperature range : -40°C/-40°F +60°C/140°F
Temperature resolution +/- 1°F
When the current temperature exceeds the maximum temperature ,it will
show maximum temperature
When the current temperature is lower than the minimum temperature, it
will show the minimum temperature .
The clock will register RF signal for 3 minutes automatically when power by
battery, then enter RCC receiving
EN
ELTRA NV
Pachtgoedstraat 2
9140 Temse
www.profile.eu
Art. 201100008
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Profile 211000008 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Profile 211000008 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info