(marked N or -). It is important to ensure that both DC clamps are making good contact with
their respective terminal posts.
Connect the charger’s AC power cable to an AC power outlet. Once you have connected the
DFC530N battery charger to AC power, it will sound a tone for 0,5 seconds and the Simple
Touch power panel LEDs light for two seconds.
3. Reverse Polarity
If the DC battery clamps are connected improperly to the battery terminals, the reverse
polarity LED will indicate the reversed polarity. The battery charger’s warning buzzer will also
sound. If this occurs simply disconnect the battery charger from the AC power. Connect the
DC clamps correctly to the battery terminals. Reconnect the charger to the AC power.
4. Charging
The battery charger is now in the Standby operating mode and the “12V”, “GEL” and “POWER”
LEDs are illuminated. This is the standard charging mode and as soon as the START button is
pressed, the charger switches immediately into the 12V GEL cell battery charging mode.
If you require an alternative selection, proceed as follows:
Step 1Select the desired battery voltage: 6V or 12V.
Step 2Select the battery type: “GEL” or “STD”
GEL indicates a common Maintenance Free battery,
e.g. Gel Cell, VRLA, AGM & etc.
STD indicates a common lead acid battery or calcium
battery.
Step 3Press the “START” button to begin charging the battery.
Battery FaultA few seconds after switching on to the operating mode, the LED indicator
“FAULT” will illuminate if the following occurs:
A. Low battery voltage - < 3 V
B. High battery voltage - > 15 V (12 V battery) / > 7,5 V (6 V battery)
C. Battery short circuit or battery cell short circuit
D. Wrong choice of voltage for the battery
Under these conditions, the battery charger will stop charging. In the event of A, B or C, the
battery may be defective and we advise you to consult your nearest battery service centre. If
the problem is attributable to D, all you have to do is select the appropriate voltage and
proceed to charge the battery.
When the LED “FULL” illuminates, the battery is completely charged. The battery charger now
switches to the Float mode and doesn’t require your attention until the next time it is used.
The DFC530N battery charger will automatically maintain your battery.
5. When charging is complete
Switch off the mains supply, unplug the charger, and disconnect the leads from the battery
posts. Inspect the liquid levels in each cell and top up. If necessary, using the correct fluid.
Replace the caps. Any surplus fluid around the cell tops should be wiped off (this should be
done with extreme care as it may be acidic/corrosive).
Where appropriate, if the battery has been removed for charging, replace it and reconnect the
cables.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pro-User DFC530N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pro-User DFC530N in the language / languages: English, German, Dutch, French, Swedish, Spanish as an attachment in your email.

The manual is 2,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info