554133
12
Zoom out
Zoom in
Previous page
1/28
Next page
12
HOW TO PUT ON THE CHEST PULSE SENSOR
The chest pulse sensor has two components: a chest
s
trap and a sensor unit (see the drawing below). Insert
the tab on one end of the chest strap into one end of
the sensor unit, as shown in the inset drawing. Press
the end of the sensor unit under the buckle on the
chest strap. The tab should be flush with the front of
the sensor unit.
Next, wrap the chest
pulse sensor around
your chest and attach
the other end of the
chest strap to the sen-
sor unit. Adjust the
length of the chest
strap, if necessary. The
chest pulse sensor should be under your clothes, tight
against your skin, and as high under the pectoral mus-
cles or breasts as is comfortable. Make sure that the
logo on the sensor unit is facing forward and is right-
side-up.
Pull the sensor unit away from your body a few inches
and locate the two electrode areas on the inner side
(the electrode areas are covered by shallow ridges).
Using saline solution such as saliva or contact lens
solution, wet both electrode areas. Return the sensor
unit to a position against your chest.
CARE AND MAINTENANCE
• Dry the chest pulse sensor after each use. The
chest pulse sensor is activated when you wet the
electrode areas and put on the chest pulse sensor;
the chest pulse sensor shuts off when it is removed
a
nd the electrode areas are dried. If the chest pulse
sensor is not dried after each use, the battery may
b
e drained prematurely.
• Store the chest pulse sensor in a warm, dry place.
Do not store the chest pulse sensor in a plastic bag
or other container that may trap moisture.
• Do not expose the chest pulse sensor to direct sun-
light for extended periods of time or to temperatures
above 122° F (50° C) or below 14° F (-10° C).
• Do not excessively bend or stretch the sensor unit
when using or storing the chest pulse sensor.
• Clean the sensor unit using a damp cloth—never
use alcohol, abrasives, or chemicals. Hand wash
and air dry the chest pulse sensor.
TROUBLESHOOTING
If the chest pulse sensor does not function prop-
erly, try the suggestions below.
• Make sure that you are wearing the chest pulse sen-
sor as described at the left. Note: If the chest pulse
sensor does not function when positioned as
described, move it slightly lower or higher on your
chest.
• Use saline solution such as saliva or contact lens
solution to wet the two electrode areas on the sen-
sor unit. If heart rate readings do not appear until
you begin perspiring, re-wet the electrode areas.
• Position yourself near the console. For the console
to display heart rate readings, the user must be
within armʼs length of the console.
• The chest pulse sensor is designed to work with
people who have normal heart rhythms. Heart rate
reading problems may be caused by medical condi-
tions such as premature ventricular contractions
(pvcs), tachycardia bursts, and arrhythmia.
• The operation of the chest pulse sensor can be
affected by magnetic interference caused by high
power lines or other sources. If it is suspected that
this is a problem, try relocating the elliptical.
HOW TO USE THE CHEST PULSE SENSOR
Chest Strap
Sensor Unit
Tab
Buckle
Sensor
Unit
Logo
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pro-form 505 ZLE - PFEVEL96010 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pro-form 505 ZLE - PFEVEL96010 in the language / languages: English as an attachment in your email.

The manual is 3,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Pro-form 505 ZLE - PFEVEL96010

Pro-form 505 ZLE - PFEVEL96010 User Manual - German - 28 pages

Pro-form 505 ZLE - PFEVEL96010 User Manual - Dutch - 28 pages

Pro-form 505 ZLE - PFEVEL96010 User Manual - French - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info