for an optimum transmission quality. Adjustable level from 1 (high level) to 9 (low
level) by rotating the channel knob.
corresponds to the Sensitivity Level.
- Anti-Vox
: allows disabling the transmission generated by the surrounding noise.
The level is adjustable from 0 (Off) to 9 (low level) by rotating the channel knob.
corresponds to Anti-vox Level.
- Delay time
: allows avoiding the sudden cut of the transmission by adding a delay
at the end of speaking. The level is adjustable from 1 (short delay) to 9 (long delay)
by rotating the channel selector. corresponds to Delay Time.
Once the adjustments are done, press during 1 second the VOX key in order to quit
the Vox Adjustment mode.
8) HI-CUT
Eliminates high frequency interferences. Has to be used in accordance with the
reception conditions. A short press activates the HI-Cut filter and «HIC» appears on
the display. A new press disables the function and «HIC» disappears.
ANL FILTER (Automatic Noise Limiter)
The transceiver is equipped with an automatic filter which reduces back ground
noises and some reception interferences in AM.
9) ROGER ~ SCAN
ROGER
(short press)
The icon «
» appears on the display when the function is active. The Roger Beep
sounds when the PTT switch of the microphone is released in order to let your corre-
spondent speak. Historically as CB is a «simplex» communication mode, it is not possible
to speak and to listen at the same time (as it is the case with a telephone). Once
someone had finished talking, he said “Roger” in order to prevent his correspondent
that it was his turn to talk. The word “Roger” has been replaced by a significant beep.
There comes “Roger beep” from.
Note: the Roger beep also sounds in the loudspeaker if the KEY BP function is active.
If the KEY BP function is not active, only the correspondent can hear the Roger Beep.
SCAN (long press)
Channel research: Allows activating the SCAN function (research of the channels) in
an increasing way. «SCN» is displayed. The scanning stops as soon as there is a busy
channel. The scanning automatically starts 3 seconds after the end of the transmission
and no key is activated during 3 s. The scanning starts again in an increasing way
by turning the rotary knob to the right, or in a decreasing way by turning the rotary
knob to the left.
A new long press on SCAN disables the SCAN function.
10) STORE ~ MEM
STORE
(long press)
Allows to memorize an emergency channel with following parameters: HI-CUT.
To memorize: Select the channel to be memorized.
- press 1 second the MEM key; «MEM» appears in the display. If the KEY BP function is
activated a long beep confirms the saving.
To delete a memory:
- switch off the transceiver.
- keep the MEM key pressed and switch on the transceiver.
- the memory is deleted.
MEM (short press)
To recall a memory:
- press MEM shortly, «MEM» appears on the display. If the KEY BP function is activated
a beep sounds. The memorized channel is activated. Short press again MEM to go
back to previous operating channel.
English
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for President Johnny III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of President Johnny III in the language / languages: English, French, Polish, Spanish as an attachment in your email.

The manual is 1,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info