Page 8
FAULT FINDING
Appliance does not operate when switched on:
• There is a 3 minute delay before the compressor starts. This is to protect
the compressor.
Appliance stops operating and “E4” is displayed on panel along with
the "TANK FULL" indicator lights.
• Bucket is full of water - empty the water as shown on page 6. Do not
drink the water (it may be used for watering plants).
• Bucket is not replaced properly. Ensure that the bucket is correctly
aligned with the housing.
Appliance stops operating and DEFROST indicator illuminates.
• This happens if the temperature is lower than 10 °C, and ice begins to
form on the internal heat exchanger. The defrost cycle will last for a few
minutes, and then operation will resume.
Appliance operates intermittently.
• The humidity in the room has reached the level set on the humidistat
control.
Very little water is extracted.
• There is very little humidity in the air (this happens during dry sunny
weather, and also during very cold weather). Condensation on windows is
caused by the difference between indoor and outdoor temperatures, and
is not a good indicator of the level of humidity.
The room remains humid and little water is extracted
• The humidity setting is too high, press the - button to reduce the required
humidity level.
• The area to be dehumidified is too large
FAULT CODES
E3 Humidity sensor fault.
E5 Pipework temperature sensor fault
If either of these faults is detected, stop the appliance by pressing the
power button. When it has stopped, switch off at the mains socket and
wait 3 minutes. Switch back on, and restart the appliance. If the fault
repeats contact your dealer.