Wet Stacking
Diesel engines are designed to operate with a load. When a diesel engine operates considerably below
the rated output level the engine can start to over fuel or “wet stack”. Diesel engines perform moste
efficiently at 70-80% of the rated output. When an engine operates for a prolonged period of time below
40% of its rated out it begins to over fuel. This occurs because the injection tips begin to carbonizes and
disrupt the fuel spray pattern. In commercial generator standby/ emergency where loads can vary and low
output conditions can occur more frequently because of the diverse load applications, an automatic load
bank is sometimes used. A load bank will place a “false” load on the generator system to keep the diesel
engine properly loaded to prevent a “wet stack” condition and automatically adjust the “false” load to the
real load.
In smaller applications a “false” load can be provided by an electric heater or other high load appliances
to ensure that the generator operating at an acceptable level. Once an engine begins to wet stack the
only way to correct the problem is to provide a high level load for an extended period of time depending
on the severity of the condition. Today`s newer emissions common rail electronic fuel injected engines
are very unlikely to create a wet stack condition, but it is possible. This is why sizing a generator for a ar
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PowerTech PTI-25-30-T4F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PowerTech PTI-25-30-T4F in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info