672551
3
Zoom out
Zoom in
Previous page
1/8
Next page
POWXG9537 EN
Copyright © 2017 VARO NV P a g e | 3 www.varo.com
5 GENERAL POWER TOOL SAFETY WARNINGS
Read all safety warnings and all instructions. Failure to follow all warnings and instructions
may result in electric shock, fire and/or serious injury. Save all warnings and instructions for
future reference. The term "power tool" in the warnings refers to your mains operated (corded)
power tool or battery operated (cordless) power tool.
6 BEFORE START-UP, NOTE THE FOLLOWING!
The pump can be connected to any shock-proof plug which has been installed according
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp.
Caution!
When the pump is to be used near swimming pools or garden ponds and in their area of
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be
operated while people are in the swimming pool or in the garden pond! Please contact your
electrician!
Attention!
(Important for your own security) Before starting to run your new submersible pump, please
have the following items checked by an expert:
Ground connection
Zero conductor
Fault current breaker switch must correspond the safety regulations of the power plants
and they must work faultlessly.
The electrical connections must be protected from moisture.
If there is danger of flooding, the electrical connections must be taken to higher ground.
Circulation of aggressive fluids, as well as the circulation of abrasive materials must be
avoided at all costs.
The submersible motor-driven pump must be protected from frost.
The pump must be protected from running dry.
Access on the part of children should also be prevented with appropriate measures.
Consistency
Your submersible pump is designed for the circulation of water with a maximum temperature
of 35° C. This pump may not be used for other fluids, especially motor fuels, cleaning fluids,
and other chemical products!
7 INSTALLATION
The submersible pump is installed as follows:
In a stationary position with fixed pipeline
or
in a stationary position with a flexible hose pipe.
Please note!
You should never install the pump by suspending it unsupported from its delivery pipe or
power cable. The submersible pump must be suspended from the specially provided handle or
be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom
of the shaft must be kept free of sludge and dirt of all kinds.
If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump
from starting up. ,Therefore it is necessary to check the submersible motor pump regularly (by
carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be
started
Note!
The pump shaft should have minimum dimensions of 40 x 40 x 50 cm, so that the floating
switch can move freely.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWXG9537 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWXG9537 in the language / languages: English as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWXG9537

Powerplus POWXG9537 User Manual - German - 8 pages

Powerplus POWXG9537 User Manual - Dutch - 8 pages

Powerplus POWXG9537 User Manual - French - 8 pages

Powerplus POWXG9537 Additional guide - All languages - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info