The compressed air produced by the compressor cannot not be used for pharmaceutical,
food or medical purposes except after particular treatments and cannot be used to fill the
air bottles of scuba divers.
6.3 Things you should know
To avoid overheating of the electric motor, this compressor is designed for intermittent
operation. In the case of overheating, the thermal cutout of the motor trips, automatically
cutting off the power when the temperature is too high. The motor restarts automatically
when normal temperature conditions are restored.
All the compressors are fitted with a safety valve that is tripped in the case of
malfunctioning of the pressure switch in order to assure machine safety.
When fitting a tool, the flow of air in output must be switched off.
When using compressed air, you must know and comply with the safety precautions to be
adopted for each type of application (inflation, pneumatic tools, painting, washing with
water-based detergents only, etc.).
7 ASSEMBLY
7.1 Point to know when setting up the compressor
Examine the machine for signs of transit damage. Report any damage immediately to the
company which delivered the compressor.
The compressor should be set up near the working consumer.
Avoid long air lines and long supply lines (extensions).
Make sure the intake air is dry and dust-free.
Do not set up the compressor in damp or wet rooms.
The compressor may only be used in suitable rooms (with good ventilation and an ambient
temperature from +5°C to +40°C). There must be no dust, acids, vapors, explosive gases
or inflammable gases in the room.
The compressor is designed to be used in dry rooms. It is prohibited to use the
compressor in areas where work is conducted with sprayed water.
7.2 Fitting the wheels
Fit the supplied wheels as shown in Fig. 3 & 4:
7.3 Fitting the supporting foot
Fit the supplied rubber stopper as shown in Fig. 5.
8 USE
8.1 Voltage
The compressor is equipped with a mains cable with shock-proof plug. This can be connected
to any 230V ~ 50Hz shock-proof socket which is protected by a 16 A fuse. Before you use the
machine, make sure that the mains voltage complies with the specifications on the rating plate.
Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede
motor start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a
result of stiffness.
8.2 Switching ON/OFF
To switch on the equipment set the On/Off push the switch (ref. 8.
Push the On/Off switch (ref. 8) again to switch off the equipment.
8.3 Adjusting the pressure
You can adjust the pressure on the pressure gauge (ref. 6) using the pressure regulator
(ref. 7).
The set pressure can be taken from the quicklock coupling (ref. 5).
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWX1751 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWX1751 in the language / languages: English as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWX1751

Powerplus POWX1751 Additional guide - English - 6 pages

Powerplus POWX1751 User Manual - German - 13 pages

Powerplus POWX1751 User Manual - Dutch - 14 pages

Powerplus POWX1751 User Manual - French - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info