POWX1724S EN
Copyright © 2020 VARO P a g e | 6 www.varo.com
7 USE OF THE COMPRESSOR
7.1 Voltage
The compressor is equipped with a mains cable with shock-proof plug. Before you use the
machine, make sure that the mains voltage complies with the specifications on the rating plate.
Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede motor
start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a result
of stiffness.
7.2 Switching ON/OFF
To switch on the equipment set the On/Off push the switch (ref. 1). Push the On/Off switch (ref.
1) again to switch off the equipment.
7.3 Adjusting the pressure
▪ You can adjust the pressure on the pressure gauge (ref. 6) using the pressure regulator
(ref. 3).
▪ The set pressure can be taken from the quick lock coupling (ref.4).
As soon as the tank pressure is built up, the motor switches off
automatically.
The motor switches automatically on as soon as the tank pressure
becomes too low.
7.4 Safety valve
The safety valve has been set for the highest permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its seal
Actuate the safety valve from time to time to ensure that it works when required. Therefore you
need to remove the protection cover.
7.5 Fitting the air filter
Remove the transportation stop with a screwdriver or similar and screw the air filter (Ref. I)
securely to the equipment (Fig. 1a-1b). If supplied, insert the suction tube inside the filter
cover (Fig. 1c).
8 CLEANING AND MAINTENANCE
8.1 Maintenance
Never clean the machine and its components with solvents, flammable or toxic liquids. Us only
a damp cloth making sure you have unplugged the compressor from the current outlet.
After approx. 2 hours of use, the condensate that has formed must be drained from the receiver.
First of all, vent all the air using the accessory connected, as described above. Back off vent
valve 5 located underneath the compressor (switched off beforehand) by two turns, taking care
to maintain the compressor in a vertical position. After draining all the water, draw up the valve
tightly.
Warning: if the water that condenses is not drained, it may corrode the
receiver, reducing its capacity and impairing safety.
As it is a contaminating product, condensate must be DISPOSED of in
accordance with laws on protection of the environment and current
legislation