Copyright © 2016 VARO NV P a g e | 5 www.varo.com
7 REMOVING PAINT
Do not use this tool to remove paint containing lead. The peelings, residue and vapors of
paint may contain lead, which is poisonous. Any pre-1960 building may have been
painted in the past with paint containing lead and covered with additional layers of paint.
Once deposited on surfaces, hand to mouth contact can result in the ingestion of lead.
Exposure even to low levels of lead can cause irreversible damage to the brain and
nervous system. Young and unborn children are particularly vulnerable.
When removing paint, ensure that the work area is enclosed. Preferably wear a dust
mask.
Do not burn the paint. Use the scraper provided and keep the nozzle at leaf 25 mm away
from the painted surface. When working in a vertical direction, work downwards to prevent
paint from falling into the tool and burning.
Dispose of all paint debris safely and ensure that the work area is thoroughly cleaned after
completing the work.
8 OPERATION
Always observe the safety instructions and applicable regulations.
Use only one hand to hold the tool Do not place your other hand over the air vents
Prior to operation:
Mount the correct accessory for the application.
Set the desired air temperature.
8.1 Switching on and off
To switch the tool on, slide the on/off switch upwards. Some smoke may be emitted after
switching on; this does not indicate a problem.
To switch the tool off, set the on/off switch to position ‘0’. Let the tool cool down before
moving or storing it.
8.2 Temperature setting
You can select the desired area of air temperature of this tool that there are there positions (II
and III) on the ON/OFF switch button when operating.
Position I: the initial temperature is 30, its purpose is reduced the cooling time after
working. To select this position, the LCD temperature display (2) shows a blue backlight.
Position II: the initial temperature is 70 and the adjustable temperature range is
70~300. To select this position, the LCD temperature display shows a green backlight.
Position III: the initial temperature is 300 and the adjustable temperature range is 300-
600. To select this position, the LCD temperature display shows a red backlight.
While select one of the positions (I, II or III), the working temperature and
setting temperature will be adjusted automatically to the initial temperature
of each position.
8.3 Air flow adjustment
This tool has an adjustment dial (5) which controls the air flow. Switch this tool on, place the
ON/OFF switch button (4) onto the position II or position III and set the desired air temperature.
To turn the adjustment dial clockwise or anticlockwise that decreases or increases the air flow,
finally select a suitable air flow for operating.
NOTE: when adjusts the air flow with the adjustment dial, the LCD temperature display shows
the corresponding positions of air flow.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWX1020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWX1020 in the language / languages: English as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWX1020

Powerplus POWX1020 User Manual - German - 10 pages

Powerplus POWX1020 User Manual - Dutch - 10 pages

Powerplus POWX1020 User Manual - French - 10 pages

Powerplus POWX1020 Additional guide - All languages - 1 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info