726325
5
Zoom out
Zoom in
Previous page
1/7
Next page
POWEW67920 EN
Copyright © 2020 VARO NV P a g e | 5 www.varo.com
Remove deposits on the floater with clear water.
9.2 Cleaning the impeller
If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1. Remove the intake cage from the pump case.
2. Clean the impeller with clear water.
Important! Do not put down or rest the pump on the impeller!
3. Re-assemble in reverse order
10 TECHNICAL DATA
type
Voltage / frequency
Power input
Delivery rate max.
Delivery height max
Immersion depth max.
Water temperature max.
For clean/dirty water:
Housing (plastic(P) / Stainless Steel (SS) )
Water inlet (plastic / Stainless Steel (SS) )
Weight
11 SERVICE DEPARTMENT
Damaged switches must be replaced by our after-sales service department.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
12 TROUBLESHOOTING
Incidents
Causes
Remedies
Pump does not start
No mains supply
Floater does not switch
Check mains supply
Bring floater in a higher
position
No flow
Inlet sieve is clogged
Pressure hose in bent
Clean inlet sieve water jet
Reset hose
Pump does not switch off
Floater cannot sink down
Place pump properly on shaft
ground
Insufficient flow
Inlet sieve is clogged
Reduced pumping capacity
by dirty and abrasive water
Clean inlet sieve
Clean pump and replace
worn-out parts
Pump switches off after
short operating period
Thermal cutout stops
pumps due to dirty water
Water too hot. Thermal-
cutout stops pump
Remove mains plug. Clean
pump and shaft
Make sure that a water tem-
perature of max. 35 °C is not
exceed
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWEW67920 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWEW67920 in the language / languages: English as an attachment in your email.

The manual is 0,22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWEW67920

Powerplus POWEW67920 User Manual - German - 8 pages

Powerplus POWEW67920 User Manual - Dutch - 7 pages

Powerplus POWEW67920 User Manual - French - 8 pages

Powerplus POWEW67920 Additional guide - All languages - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info