Proper adjustment of the in-line lubricator is performed by placing a sheet of paper next to
the exhaust ports and holding the throttle open approximately 30 seconds. The lubricator is
properly set when a light stain of oil collects on the paper. Excessive amounts of oil should
be avoided.
In the event that it becomes necessary to store the tool for an extended period of time
(overnight, weekend, etc.), it should receive a generous amount of lubrication at that time.
The tool should be run for approximately 30 seconds to ensure oil has been evenly
distributed throughout the tool. The tool should be stored in a clean and dry environment.
It is most important that the tool be properly lubricated by keeping the air line lubricator
filled and correctly adjusted. Without proper lubrication the tool will not work properly
and parts will wear prematurely.
Use the proper lubricant in the air line lubricator. The lubricator should be of low air flow
or changing air flow type, and should be kept filled to the correct level. Use only
recommended lubricants, specially made for pneumatic applications. Substitutes may
harm the rubber compounds in the tools, O-rings and other rubber parts.
7 IMPORTANT!!!
If no filter/ pressure regulator/ lubricator is installed in the compressed air system, then
pneumatic tools must be lubricated with 2 to 6 drops of oil at least once a day or after every
two hours of use. This must be done directly along the male coupler or the screw (OIL)
provided for the purpose on the side of the tool’s housing.
Automatic lubrication is also possible using the supplied mini oiler that you have to install
between the threaded connector of the tool and the male coupler. Make sure that the oiler
is always filled with suitable oil.
Fig. 1
1. Tool
2. Quick connector
3. Quick coupler
4. Air hose
5. Quick connector
6. Quick coupler
7. Lubricator
8. Regulator (0-8.5 bar)
9. Filter
10. Cut-off valve
11. Air compressor
8 MAINTENANCE
Disconnect the tool from the compressor before adjusting, clearing jams,
servicing &maintenance, relocating and during non operation.
Regular lubrication, if your tool without using the in-liner automatic oilier, place 2 or 6
drops of pneumatic tool oil into the air inlet before each work day or after 2 hours of
continuous use depending in the characteristic of work piece or type of fasteners.
Air-operated tools must be inspected periodically, and worn or broken parts must be
replaced to keep the tool operating safely and efficiently. Check and change all worn or
damaged O-ring, Seals, etc. Tight all the screws and caps in case personal injury.
Make regular inspection for free movement of trigger, Spring and safety mechanism to
assure safe system is complete and functional: no loose and missing parts, no building
or stocking parts.
Keep magazine and nose of tool clean and free of any dirt lint or abrasive particles.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerplus POWAIR0311 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerplus POWAIR0311 in the language / languages: English as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerplus POWAIR0311

Powerplus POWAIR0311 User Manual - German - 9 pages

Powerplus POWAIR0311 User Manual - Dutch - 9 pages

Powerplus POWAIR0311 User Manual - French - 9 pages

Powerplus POWAIR0311 Additional guide - All languages - 3 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info