754130
49
Zoom out
Zoom in
Previous page
1/56
Next page
POWERFIX PDM 250 A2
English - 47
Resistance measurement
Ensure that all circuit elements, circuits and components to be measured and other test
objects are completely switched off and discharged. Otherwise, the multimeter could be
damaged.
Connect the black test lead to the COM jack [5] and the red test lead to the mA/Ω/BATT
jack [9].
Set the range selector switch [4] to the desired range in the Ω measuring range.
Connect the test probes [7] to the test object.
The measurement result is then indicated on the display [1].
For resistances > 1MΩ, the measurement may take a few seconds. In this case, wait until the
measured value has stabilised.
The test probes [7] should be handled only behind the finger protection to avoid a distorted
measurement result.
For measurements of low resistances (200Ω range), the internal resistance of the test leads
can lead to a distorted result. To avoid such an error, note the value of the measurement for
short-circuited test probes and deduct this from the value of the actual measurement.
Continuity test
Ensure that all circuit elements, circuits and components to be measured and other test
objects are completely switched off and discharged. Otherwise, the multimeter could be
damaged.
Connect the black test lead to the COM jack [5] and the red test lead to the mA/Ω/BATT
jack [9].
Set the range selector switch [4] to the position in the Ω measuring range.
Connect the test probes [7] to the test object.
If the resistance is less than approximately 60Ω, the buzzer sounds and the measurement
result is indicated on the display [1].
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Powerfix PDM 250A2 - IAN 108029 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Powerfix PDM 250A2 - IAN 108029 in the language / languages: French as an attachment in your email.

The manual is 8,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Powerfix PDM 250A2 - IAN 108029

Powerfix PDM 250A2 - IAN 108029 User Manual - English, German, Dutch, Danish, Swedish, Finnish - 106 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info