8.113. PEQOF -- Set Frequency Parameter for Specified
Parametric EQ Output Stage
This command sets or queries the frequency parameter (in Hz) for the parametric equalizer (EQ) filters on output
channels 1-8 and A-D . Each channel has five bands of parametric EQ that can be independently controlled.
The minimum and maximum values for the frequency parameter are 20 and 20000, respectively.
For filter types that have a center frequency (e.g., parametric), this parameter specifies the center frequency. For
filter types that have a cutoff frequency (e.g, highpass, lowpass, etc.), this parameter specifies the cutoff
frequency.
This command has the same format and restrictions as the
PEQOA command except that only one parameter, the
frequency, is specified instead of all the parameters. See the
PEQOA command for more information. To set the
frequency parameter for an input parametric EQ filter, use the
PEQIF command. To set all the parameters for an
input parametric EQ filter, use the
PEQIA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
F01PEQOF3,2,1250
Set frequency of parametric EQ
on output 3 , band 2 to 1250 Hz.
F01PEQOF3,2,1250
F01PEQOFB,1,?
Query current frequency setting
of parametric EQ on output B ,
band 1.
F01PEQOFB,1,f , where f is the current setting of
the frequency parameter for the parametric EQ on
output B , band 1. If the frequency parameter of this
filter is set to the same value given in the example
above, then the status message will be
F01PEQOFB,1,1250 .
8.114. PEQOG -- Set Gain Parameter for Specified Parametric EQ
Output Stage
This command sets or queries the gain parameter (in dB) for the parametric equalizer (EQ) filters on output
channels 1-8 and A-D . Each channel has five bands of parametric EQ that can be independently controlled.
The minimum and maximum values for the gain parameter are -20 and 20, respectively.
This command has the same format and restrictions as the
PEQOA command except that only one parameter, the
gain, is specified instead of all the parameters. See the
PEQOA command for more information. To set the gain
parameter for an input parametric EQ filter, use the
PEQIG command. To set all the parameters for an input
parametric EQ filter, use the
PEQIA command.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polycom Vortex EF2280 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polycom Vortex EF2280 in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polycom Vortex EF2280

Polycom Vortex EF2280 User Manual - English - 62 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info