running. For example, if you have created new sport (Jogging) in WebSync software, you need to calibrate
the stride sensor for that sport also.
If you select Running as your sport profile and do walking activities, there is no need to calibrate the s3+ stride
sensor.
Calibration by Running Wizard
Before you can calibrate the stride sensor it needs to be paired with the training computer. For more
information on pairing the stride sensor and training computer, see Using a New Accessory (page 42).
Make sure the stride sensor function in the training computer is on. Select Settings > Sport profiles >
Running> Stride sensor > On.
To calibrate a certain distance with a step-by-step guidance, select
1. Settings > Sport profiles > Running > Stride sensor calibration > By running.
2. Adjust the distance, how far you wish to run, to calibrate the stride sensor and press the OK to confirm.
Stand still until stride sensor is found is displayed.
3. Press OK and run ... km/mi is displayed.
4. Press the OK and start the run by making the first step with the sensor foot onto the starting line and run
the preset distance at a steady pace.
5. Press OK after xxx km/mi is displayed.
6. Stop exactly on the finish line of the preset distance. Press OK.
7. When the calibration succeeds, Calibrated to x.xxx is displayed. The new calibration factor is used.
8. If the calibration fails, Calibration failed is displayed. If you cancel the calibration by pressing the STOP
button, Calibration canceled is displayed.
9. After calibration, Continue recording? is displayed. If you wish to continue session, select Yes.
Otherwise, select No.
Set Calibration Factor Manually
The calibration factor is calculated as a ratio of the actual distance to the uncalibrated distance. Example:
you run 1200m, and the training computer shows a distance of 1180m, the calibration factor is 1.000.
Calculate the new calibration factor as follows: 1.000*1200/1180 = 1.017. The measuring range for the
factor is 0.500-1.500.
To calibrate the stride sensor manually before training, select
1. Settings > Sport profiles > Running> Stride sensor > Set factor
2. Adjust the factor.
The calibration factor can also be set during training, when the stride sensor is in use. Press and hold
LIGHT to go to Quick menu > Calibrate stride sensor > Set factor .
*Optional s3+ stride sensor required.
Calibrate Sensor by Running a Known Distance (on-the-fly calibration)
You can calibrate the sensor at any phase of your training with lap distance correction, provided you are
not training with distance-based targets. Just run a known distance, preferably more than 1000 meters.
Make sure the stride sensor function in the training computer is on. In Time mode press UP and select
Settings > Sport profiles > Running> Stride sensor > On.
1. In time mode press OK once. Browse the sport profiles with UP/DOWN and select Running by pressing
OK. Start running.
2. When you are at a starting point of a known lap distance, press OK. When you have run the whole lap
distance, press OK.
3. Then calibrate the sensor: Press and hold LIGHT to go to Quick menu > Calibrate stride sensor.
ENGLISH
Prepare for Training 11
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Polar RCX5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Polar RCX5 in the language / languages: English as an attachment in your email.

The manual is 1,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Polar RCX5

Polar RCX5 User Manual - German - 68 pages

Polar RCX5 User Manual - Dutch - 63 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info