717518
58
Zoom out
Zoom in
Previous page
1/87
Next page
58
2.4.1 Connection diagram
Voltage heating elements 230V.
Any kind of connection: the
safety wire must be connected to
the PE terminal.
Recommended
type of
connection
lead.
1
For 230 V earthed one-phase
connection.
Bridges connect 1 - 2 - 3
terminals and 4 - 5 terminals.
Protective ground to
H05VV-F3G4
2
For 400 / 230 V earthed
two-phase connection.
Bridges connect 2 - 3
terminals and 4 - 5 terminals.
Protective ground to
H05VV-F4G2,5
3
For 400 / 230 V earthed
three-phase connection.
Bridges connect 4 - 5
terminals, phases in
succession 1, 2 and 3,
Neutral to 4 - 5.
Protective ground to
H05VV-F5G1,5
L1=R, L2=S, L3=T
N= Earth
PE= earth wire terminal
1. Check that the technical data of your energy supply meet the values on the
nameplate.
2. Your domestic circuit must be equipped with an automatic circuit breaker.
3. Do not attempt to repair the appliance yourself. Repairs carried out by
unauthorized persons can cause serious damage. Always contact the nearest
service centre. Original spare parts should be used only..
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for PKM BIC8 2KB GK IX-2 H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of PKM BIC8 2KB GK IX-2 H in the language / languages: English, German as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info