The Advanced MCACC menu 10
87
En
Using Acoustic Calibration EQ Professional
1 Select ‘EQ Professional’, then press ENTER.
2 Select an option and press
ENTER
.
Reverb Measurement – Use this to
measure the reverb characteristics of your
room.
Reverb View – You can check the reverb
measurements made for specified
frequency ranges in each channel.
1
Advanced EQ Setup – Use this to select
the time period that will be used for
frequency adjustment and calibration,
based on the reverb measurement of your
listening area. Note that customizing
system calibration using this setup will
alter the settings you made in
Automatically setting up for surround
sound (Auto MCACC) on page 37 or
Automatic MCACC (Expert) on page 78 and
is not necessary if you’re satisfied with
these settings.
3 If you selected ‘
Reverb Measurement
’,
select
EQ
ON
or
OFF
, and then
START
.
The following options determine how the
reverb characteristics of your listening area are
displayed in Reverb View:
EQ OFF – You will see the reverb
characteristics of your listening area
without the equalization performed by this
receiver (before calibration).
EQ ON – You will see the reverb
characteristics of your listening area with
the equalization performed by this receiver
(after calibration).
2
Note that the EQ
response may not appear entirely flat due
to adjustments necessary for your listening
area.
3
When the reverb measurement is finished, you
can select Reverb View to see the results on-
screen. See Professional Calibration EQ
graphical output on page 107 for
troubleshooting information.
Note
1If the Reverb View procedure is performed after the Automatically setting up for surround sound (Auto MCACC) on
page 37 or Reverb Measurement operation, depending on the standing wave control setting, differences may
appear on the reverb graph. With the Auto MCACC function, the reverberations are measured with the standing waves
controlled, so the reverb characteristics graph shows the characteristics with the effect of the standing waves
eliminated. By contrast, the Reverb Measurement function measures the rever berations without controlling the
standing waves, so the graph indicates the reverb characteristic
s including the effect of the standing waves. If you
wish to check the reverb characteristics of the room itself (with the standing waves as such), we recommend using
the Reverb Measurement function.
1. Fine Channel Level
2. Fine SP Distance
3. Standing Wave
1c.Manual MCACC
4. EQ Adjust
5. EQ Professional
A/V RECEIVER
Exit Return
a. Reverb Measurement
b. Reverb View
c. Advanced EQ Setup
1c5.EQ Professional
A/V RECEIVER
Exit Return
2 The calibration corresponding to the currently selected MCACC preset will be used when EQ ON is selected. To use
another MCACC preset, exit the HOME MENU and press MCACC to select it before pressing HOME MENU.
3After auto calibration with EQ Type : SYMMETRY (Full Auto MCACC, etc.), the graph for the inferred reverb
characteristics can be displayed by selecting Reverb View. To display the actually measured reverb characteristics
after EQ calibration, measure with EQ ON.
MCACC : M1.MEMORY 1
1c5a.Reverb Measurement
A/V RECEIVER
Exit Cancel
START
Reverb Measure with : EQ OFF
VSX-1019_KU.book 87 ページ 2009年2月17日 火曜日 午前11時56分
87


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pioneer VSX-1019AH-K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pioneer VSX-1019AH-K in the language / languages: English as an attachment in your email.

The manual is 9,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Pioneer VSX-1019AH-K

Pioneer VSX-1019AH-K User Manual - German - 127 pages

Pioneer VSX-1019AH-K User Manual - Dutch - 127 pages

Pioneer VSX-1019AH-K User Manual - French - 127 pages

Pioneer VSX-1019AH-K User Manual - Italian - 127 pages

Pioneer VSX-1019AH-K User Manual - Swedish - 251 pages

Pioneer VSX-1019AH-K User Manual - Spanish - 127 pages

Pioneer VSX-1019AH-K User Manual - Norwegian, Finnish - 251 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info