541892
13
Zoom out
Zoom in
Previous page
1/64
Next page
Oscilloscope Diagnostics Kit Quick Start Guide Pico Technology
6 DO110-4
The first drop-down menu selects the range of signal that you are interested in
measuring. If any custom ranges are defined, these will also be displayed here.
The second drop-down menu selects either AC or DC coupling.
The third drop-down menu selects a vertical zoom factor of x1, x2 or x5, allowing smaller
details in the signal to be viewed.
Additional information on the rest of the drop-down menus in the top toolbar can be
found in the help menu installed with the software.
On the bottom toolbar, the ‘STOP’ / ‘GO’ button starts and stops the capturing of
waveforms (the spacebar has the same effect). When you stop the oscilloscope, it will
hold the last waveform on the display.
The bottom toolbar also contains the controls for setting up the triggering conditions for
the oscilloscope. Triggering is used to select the moment when PicoScope starts to collect
data to display. This is usually at some fixed time before or after a trigger event. There is
only one set of trigger settings, which applies to all views.
A trigger event occurs when a specified channel crosses a voltage threshold (while rising
or falling). PicoScope can start collecting data immediately after the trigger event or at a
fixed time interval before or after the trigger event.
After PicoScope has collected a block of data and displayed it, it can either start looking
for the next trigger event (repeat mode), or stop collecting (single mode), leaving the
data after the trigger on the display.
3.5 Making your first measurement
We suggest that you first use the Oscilloscope Diagnostics Kit to capture the current and
voltage waveforms from the alternator. You will find this option in the Automotive Menu
under Miscellaneous | Charging circuits | Current / Volts. The help page that
appears automatically will show you how to connect the different parts of the
Oscilloscope Diagnostics Kit and give you a basic understanding of the kit.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Pico Technology Diagnostics Kit at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Pico Technology Diagnostics Kit in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 8,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info