643484
7
Zoom out
Zoom in
Previous page
1/72
Next page
SEE VENT
MANUFACTURER'S
INSTRUCTIONS
MIN 4"
4"
6"
6"
32"
FLOOR PROTECTION
REAR WALL
SIDE WALL
HEAT RADIATION AREA
6"
6"
4"
4"
6"
32"
FLOOR PROTECTION
SIDE WALL
REAR WALL
SEE VENT MANUFACTURER'S
INSTRUCTIONS
HEAT RADIATION AREA
Fig. 4
Fig. 5
SEE VENT
MANUFACTURER'S
INSTRUCTIONS
MIN 22"
(MIN 56 cm)
Fig. 6 Fig. 7
Install the product in compliance with the recommended safety distances
from heat sensitive or inammable materials and not inammable, from
load bearing and other walls and also from wooden elements, furniture,
etc.
The minimum distances are:
- 4” (10 cm) from the wall behind the stove;
- 6” (15 cm) from the side wall;
- 32” (80 cm) in the heat radiation area and from the the hot air fan
outlet.
In the case of ooring that is heat sensitive or inammable the oor
must be protected with non-combustible material, e.g. sheets of steel
plate, marble, tiles, stone, brick, etc.
The oor protection must extend:
- under the product;
- a minimum of 6” (152 mm) in front of unit and beyond each side of
the fuel loading and ash removal opening (4” / 10cm from the external
side of the coating).
Connection to the ue must respect minimum safety distances from
heat-sensitive structural components or inammable materials (wood
panelling, beams or ceilings, etc) shown in gures.
a The stove will become hot while in operation. Keep children
away from all stove surfaces.
Direct contact with stove while operating may cause skin
burns.
a Keep any combustible product such as wooden furniture,
curtains, carpets, combustible liquids, etc. well away from the
stove when it is lit (minimum distance 32” / 80 cm).
a It is recommended that greater distances than those indicated
above be left all round the stove to make any necessary work
on the appliance easier.
a INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
a Certain local code restrictions may apply.
Check with Local Ofcials rst before installing.
DT2011553-02
1.6 MINIMUM SAFETY DISTANCES
H07032120 / DT2002308 – 00
7
English
DT2033045-01
DT2033046-01
DT2033043-00 DT2033044-01
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Piazzetta P963 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Piazzetta P963 in the language / languages: English as an attachment in your email.

The manual is 4,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info