643476
23
Zoom out
Zoom in
Previous page
1/64
Next page
Power cable (6)
•The stove/rebox comes with a power cable which must be connected
to a 120V AC electrical outlet mains socket. Connection to the rear of
the stove/rebox is shown in g. 42.
•The power rating is indicated in the paragraph “TECHNICAL DATA”.
a The appliance must be connected to an efcient earthing/
grounding system.
a Any stove installed in a mobile home must be electrically
grounded to the steel chassis of the home and bolted to the
oor in Model compliance with, and according to building
code requirements.
a Ensure that in its normal position the power cable does not
come into contact with any heated parts.
a Ensure that the electrical plug is accessible also after
installation of the stove.
a In Canada, the electrical installation must meet the appliance
requirements for CSA C22.2
Room sensor connection (5)
•When installing the stove/rebox, it is necessary to connect the room
sensor (provided) to the correct jack (Fig. 40). The sensor can be
positioned as shown in g. 41, otherwise remove the band, uncoil the
lead and then place the sensor in a spot where a more accurate room
temperature reading can be obtained.
Pipe tap (3)
•The appliance has an external socket for measuring the pressure
(vacuum) of the ue gas outlet pipe. This control and verication should
be carried out by authorised personnel at the time of installation or
during maintenance.
Connection to the DB9 serial socket (7)
•The appliance has a DB9 serial socket, which is used to check
appliance operation. Controls should be carried out by authorised
personnel at the time of installation or during maintenance.
1
4
3
2
7
Fig. 40
1 External jack for connection of
room sensor
2 Socket for power lead
3 Pipe tap
4 Knockout for inserting cable gland
PG7 for connection of external
thermostat
6
5
Fig. 41 Fig. 42
5 Room sensor connection
6 Power lead connection
7 DB9 serial socket
DT2010146-00
5.2 ELECTRICAL CONNECTIONS ANd CONTROLS
The appliance is designed for connection to an external room thermostat
(not included in the package).
To connect the thermostat use a 2x0.5 mm
2
cable secured with a PG7
cable gland to be inserted in the relative hole in the rear panel (Fig. 40).
Only authorised personnel should carry out this operation.
a Installation can be carried out with any type of room thermostat
but requires a PG7 cable gland similar to that shown in g. 44.
To connect the room thermostat to the electronic board, refer
to the wiring diagram.
To install, proceed as follows:
- cut off the electricity to the appliance before opening it;
- remove the electronic board protective panel (Fig. 44);
- remove the knockout to be found in the rear panel (position 4 – gure
40);
- clamp the thermostat cable with the PG7 cable gland and insert the
gland into the hole in the rear panel (Fig. 45);
- connect the thermostat terminal to the 2-pin terminal of the electronic
board (see WIRING DIAGRAM);
- replace the electronic board protective panel.
DT2010147-03
5.3 INSTALLING ThE ExTERNAL ThERMOSTAT
1
2
3
4
Fig. 43
1 Thermostat
2 Electronic board 2-pin terminal
3 Cable gland PG 7
4 Thermostat cable terminal
ELECTRONIC BOARD
PROTECTIVE PANEL
Fig. 44 Fig. 45
H07028100/DT2000970 – 01
23
English
DT2030224-01
DT2030225-01 DT2030226-01
DT2030076-00
DT2030227-01 DT2030228-00
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Piazzetta P960 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Piazzetta P960 in the language / languages: English as an attachment in your email.

The manual is 2,34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info