The stove may be connected to an existing Class A chimney or a masonry
chimney which meets the minimum requirements of NFPA 211. Using
this kind of installation the pellet stove is able to draft naturally without
exhaust blower operation (failure), reducing the probability of burn-back
and back-drafting.
a Check that the connection to the ueway is gas/smoke-tight,
since the appliance operates in a vacuum.
If you wish to use an existing chimney it is strongly recommended that
you have it checked by a professional chimneysweep to ensure that it
is completely airtight (Fig. 12). The reason for this is that the smoke,
because it is slightly pressurised, can inltrate any cracks in the ue
and escape into living spaces. If upon inspection you nd that the
chimney is not completely sound, a relining of the chimney with either
PL vent or single wall stainless steel pipe may be necessary to bring
the chimney into compliance. If the existing chimney is wide enough
we recommend a pipe with a maximum diameter of 6”.
Put attention: some areas require that a liner must be always installed
to the top of the ue, as shown in gure even if the existing chimney
is in compliance (Fig. 13).
When chimneys are relined, a chimney chase cap that reduces the
outlet of the chimney to the size of the liner is required. Extend the
exhaust vent above the chimney chase cap and nish it off with a
rain cap. A single wall liner may need to be insulated to maintain
adequate exhaust temperatures in the vent system.
a Outside Chimneys frequently are difcult to keep warm: it is
recommended that you insulate the liner.
Venting into the side of an existing masonry chimney must be done
through a masonry thimble. When wall penetration is necessary to
access a masonry chimney, use a listed PL vent wall thimble (Fig.
12-13).
When venting into a Class A steel chimney, (Fig. 14), use an appropriate
PL Vent adapter.
a Strictly observe the PL Vent manufacturer’s safety
specications.
a INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
a Ensure that all installation work is carried out to professional
standards.
DT2010232-02
1.9 CONNECTING TO A CONVENTIONAL CHIMNEY
MASONARY MUD THIMBLE
PL ADAPTER
TEE (T)
VENT
SOOT
INSPECTION
APERTURE
PL ADAPTER
TEE (T)
VENT
MASONRY MUD THIMBLE
SOOT
INSPECTION
APERTURE
TEE
FRESH AIR
INTAKE
VENT
PL VENT ADAPTER
SEE VENT
MANUFACTURER'S
INSTRUCTIONS
Fig. 12
Fig. 13
Fig. 14
H07031310 / DT2002112 – 00
11
English
DT2033037-01
DT2033036-01
DT2033038-01
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Piazzetta P958 D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Piazzetta P958 D in the language / languages: English as an attachment in your email.

The manual is 5,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info