To ensure trouble-free operation the stove must have the necessary
air available for combustion and this is provided through the fresh air
intake.
The fresh air intake must:
- have a total free cross section at least equal to the size given in the
paragraph “TECHNICAL DATA”;
- be protected by a grille or suitable guard provided it does not reduce
the minimum recommended section;
- be in a position whereby it cannot be obstructed.
It is recommended that the stove be connected to an outside source of
combustion air under certain conditions (negative pressure).
To install outside air use any 2” I.D. exible metal hose or rigid metal
pipe (conduit).
It must be connected around (NOT INSIDE) the combustion air inlet tube
(Fig. 3).
Increase the outside air pipe diameter to 3” for runs over 15 ft (4,5 m)
and elevation over 4 ft (1 m).
a Long runs should be avoided.
Be careful not to pinch or bend the outside air pipe with too small a
radius.
Outside Air Pipe may be terminated ush with the outside wall but
should be protected from wind and weather by a hood.
a The outside air pipe must terminate above the maximum
snow line and below the exhaust vent outlet.
Take care not to draw cold air past water pipes that may freeze.
An open mesh screen should be placed over the outside air pipe opening
to prevent birds or rodents from nesting in the opening. Use an elbow or
shield to prevent prevailing winds from blowing directly into the outside
air intake pipe.
NOTE: Mesh screen should be no smaller than 1/4” by 1/4” (6,4 by 6,4
mm).
a Outside combustion air is required for all mobile home
installations and where building codes require.
a In bedroom or bathroom installations the outside air
connection is required.
DT2010539-03
1.2 FRESH AIR INTAKE
DT2010539-03
1.3 OUTSIDE COMBUSTION AIR
2" O.D.
COMBUSTION AIR TUBE
Fig. 2
Fig. 3
H07031310 / DT2002112 – 00
5
English
DT2030054-00
DT2033383-00
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Piazzetta P958 D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Piazzetta P958 D in the language / languages: English as an attachment in your email.

The manual is 5,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info