445450
16
Zoom out
Zoom in
Previous page
1/82
Next page
- It prevents malfunctioning
If the descaling procedure is not performed correctly, scale residue remains
behind in the machine. This causes scale to build up more quickly and may
cause permanent and irreparable damage to the machine.
Use the correct descaling agent
Only citric acid-based descalers are suitable for descaling the SENSEO
®
machine. This type of descaler descales the appliance without damaging
it. For the correct amount, see under ‘Descaling procedure’ below. Each
descaling mixture can be used only once. After use, the descaling mixture is
no longer active.
We advise you to use the special SENSEO
®
Descaler (HD7006). Read the
instructions on the package of the descaling agent.
Never use a descaling agent based on mineral acids such as sulphuric
acid, hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar). These
descaling agents may damage your SENSEO
®
coffee machine.
Descaling procedure
1 Mix 50 grams of citric acid with 1 litre of water in a measuring jug.
Stir until the powder is completely dissolved.
2 Fill the water reservoir up to the MAX indication with the descaler
mixture. Then put the water reservoir back into the coffee machine.
Note: Not all SENSEO
®
machine types have a water reservoir with a capacity
of 1 litre. If you have a SENSEO
®
machine with a smaller water reservoir,
repeat steps 2 to 6 with the remainder of the mixture without lling the water
reservoir up to the MAX indication.
3 Press the on/off button 3.
The machine is ready for use when the indicator light lights up continuously.
4 Place the 1-cup pod holder q with a used coffee pod in it in the
coffee machine. Close the lid and make sure it is properly locked.
Note: Always put a used coffee pod in the pod holder when you descale the
machine. This pod serves as a ‘lter’ to prevent the sieve or hole in the pod
holder from getting clogged with scale residue.
5 Put a bowl with a capacity of at least 1500ml under the spout to
collect the descaling mixture.
6 Press the 2-cup button qq and let the machine operate. Repeat this
until the water reservoir is empty.
Never interrupt the descaling process!
7 Repeat steps 1 to 6. Replace the used pod with another used pod to
lter out the scale residue.
Note: To descale properly, you have to use 2 litres of descaling mixture.
Never descale the SENSEO
®
coffee machine with the lid open. Make sure
the lid is properly locked.
ENGLISH16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Philips Senseo HD 7822 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Philips Senseo HD 7822 in the language / languages: English, Danish, Swedish, Norwegian, Finnish as an attachment in your email.

The manual is 2,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Philips Senseo HD 7822

Philips Senseo HD 7822 User Manual - German, Dutch, French - 54 pages

Philips Senseo HD 7822 Manual - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info